Samsung SL-X7600GX Service Manual page 283

A3 color copier
Table of Contents

Advertisement

Code
Display
112-0170 Manual Color Regi Y-offset Magenta
112-0180 Manual Color Regi Y-offset Cyan
112-0190 Manual Color Regi Y-offset Black
112-0240 Manual Color Regi Left Width Yellow
112-0250 Manual Color Regi Right Width Yellow
112-0260 Manual Color Regi Left Width Magenta
112-0270 Manual Color Regi Right Width Magenta
112-0280 Manual Color Regi Left Width Cyan
112-0290 Manual Color Regi Right Width Cyan
112-0300 Manual Color Regi Left Width Black
112-0310 Manual Color Regi Right Width Black
112-0320 Color Regi LSU Skew Yellow
112-0330 Color Regi LSU Skew Magenta
112-0340 Color Regi LSU Skew Cyan
Engine Test Routines
Diagnostics > Engine Diagnostics > Engine Test Routines
Purpose
Operation Procedure
Verification
Specification
Reference
Code
Displayed Name
100-0041
OPC Motor Y
100-0042
OPC Motor M
100-0043
OPC Motor C
100-0044
OPC Motor K
100-0046
Y OPC Motor Ready
100-0047
M OPC Motor Ready
100-0048
C OPC Motor Ready
100-0049
K OPC Motor Ready
100-0074
Opc Fan Run
100-0075
Opc Fan Ready
100-0080
T1 Engage Motor
Copyright© 1995-2013 SAMSUNG. All rights reserved.
To perform test routines for the engine.
When the main Engine Test Routines window displays, engineer can navigate through the list of
routines that display along with their descriptions. Engineer can also directly input an EDC code to
the text box to find a routine. Users can select a maximum of 3 routines at the same time.
After selecting one or multiple routines, pressing the "OK" button will open the test window that lists
selected routines. Engineer can start/stop a desired test routine.
N/A
N/A
N/A
Meaning
Distant from psync to Image area for
Magenta
Distant from psync to Image area for Cyan
Distant from psync to Image area for Black
Image Area Left Width for Yellow
Image Area Right Width for Yellow
Image Area Left Width for Magenta
Image Area Right Width for Magenta
Image Area Left Width for Cyan
Image Area Right Width for Cyan
Image Area Left Width for Black
Image Area Right Width for Black
LSU Skew for Yellow
LSU Skew for Magenta
LSU Skew for Cyan
Meaning
Yellow Opc BLDC Motor is On/Off
Magenta Opc BLDC Motor is On/Off
Cyan Opc BLDC Motor is On/Off
Black Opc BLDC Motor is On/Off
Detect if Yellow OPC BLDC Motor runs at normal
speed
Detect if Magenta OPC BLDC Motor runs at normal
speed
Detect if Cyan OPC BLDC Motor runs at normal speed
Detect if Black OPC BLDC Motor runs at normal speed
Start/Stop Opc Fan run
Detects if Opc Fan runs at normal speed.
T1 Engage Motor On/Off
4. Troubleshooting
Default
Max/Min
200
400 / 0
200
400 / 0
200
400 / 0
500
1000 / 0
500
1000 / 0
500
1000 / 0
500
1000 / 0
500
1000 / 0
500
1000 / 0
500
1000 / 0
500
1000 / 0
200
400 / 0
200
400 / 0
200
400 / 0
4-32