Administrator Operations
2.4

Canceling the Operation Prohibited State

When access to the Administrator Setting mode by the Administrator of the
machine via the control panel is authenticated, the machine enables the op-
eration of Release Setting performed for canceling the state of Prohibit Func-
tion When Auth. Error (access lock state) as a result of unauthorized access.
Release Setting clears the unauthorized access check count for all User Au-
thentication, SNMP authentication, all Secure Print authentication, and all
User Box authentication, resetting it to zero.
Perform the following procedure to cancel the password entry prohibited
state.
- Administrator Setting mode: Turning OFF/ON the main power switch
- User/Group authentication: Release or turning OFF/ON the main power
switch
- Secure Print authentication: Release
- User Box authentication: Release or turning OFF/ON the main power
switch
- SNMP authentication: Release or turning OFF/ON the main power switch
2.4.1

Performing Release Setting

Note
When the main power switch is turned off, then on again, wait at least 10
seconds to turn it on after turning it off. if there is no wait period between
turning the main power switch off, then on again, the machine may not
function properly.
Here is the sequence, through which the main power switch and sub
power switch are turned on and off:
Turn off the sub power switch
on the main power switch
Do not leave the machine with the Administrator Setting mode setting
screen left shown on the display. If it is absolutely necessary to leave the
machine, be sure first to log off from the Administrator Setting mode.
<Setting can be made only from the control panel>
0 For the procedure to call the Security Details menu to the display, see
steps 1 and 2 of "Setting Prohibit Function When Auth. Error" on
page 2-15.
1
Call the Security Details to the screen from the control panel.
C300
Turn off the main power switch
Turn on the sub power switch
2
Turn
2-17