Pentair intellidrive pid10 Owner's Manual page 15

Hide thumbs Also See for intellidrive pid10:
Table of Contents

Advertisement

Available languages

Available languages

Programming
Table 5 - Continued
Menu or
Parameter
Sub Menu
Excessive
Runtime
Detection
Ex Runtime
Excessive
Runtime Hours
Auto Restart
Delay
Number of
Resets
Detection Time
Dry Run
Sensitivity
Fill Time
Digital Input 1
Digital Input 2
I/O
Relay Output
Over Press
Over Pressure
No Ground
No Ground
Detection
Reset
Factory Reset
SW Update
Software Update
Unit of Measure
Default
_
Disabled
Hours
24
Minutes
10 Min
3
M:SS
15 Sec
PSI
10
M:SS
1 M
Unused
Unused
PSI
80 PSI
Enabled
No
Disabled
Value
Min
Max
Disabled
Enabled
1
100
3 Min
60 Min
0
5
5 Sec
10 Min
0
300
15 S
10 M
15 PSI
97 PSI
Disabled
Enabled
No
Yes
Disabled
Enabled
Description
Enables or disables Excessive Runtime
Detection.
Number of hours Drive can run before it
faults on Excessive Runtime.
Time Drive waits to restart pump when
Dry Run is detected.
Number of tries Drive attempts to restart
pump when Dry Run condition is
detected.
Time the Drive takes to recognize Dry
Run condition.
Pressure value that Dry Run condition
is detected at. Dry Run fault will occur
if this pressure cannot be met within
Detection Time window. Lower pressure
= less sensitivity.
Time allowed to fill (prime) pipes during
Auto Line Fill process. Relates to Dry Run
Sensitivity value. (Time starts after 55 Hz
is reached).
Selects operation of Drive when terminal
I1 or I2 is used. Select between Unused,
Run Enabled, Ext Fault, and Setpoint. The
Drive will respond to selected command
when voltage is present at I1 or I2
terminal.
Selects the operation of Drive when
terminal O1 is used. Select between
Unused, Run, and Fault. The Drive closes
the Relay when Run or Fault is selected.
Sets Over Pressure Warning value.
Change if higher than 80 PSI system
pressure is needed.
Selects whether Ground Detection
parameter is Enabled or Disabled. If
Disabled is selected, it will revert back to
Enabled after 72 hours. Warning LED will
flash entire time it is Disabled.
Resets all parameters to factory defaults.
Displays Setup Guide after it is complete.
Software version displayed here. Does
not clear fault log.
Used to update software, if necessary.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellidrive pid20Intellidrive pid50Intellidrive pid30

Table of Contents