Top Vent - Horizontal Termination - (continued)
Two Elbows
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when
using fl ex vent except when
using the simple up and out
installation. See Figure 4.8.
WARNING *
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fi replaces, a one foot minimum
vertical vent section is required before installing
fi rst elbow.
• When using DVP-TB1 termination cap on top vented
fi replaces, a three foot minimum vertical vent section is
required before installing fi rst elbow.
H
Figure 4.11
20
2
INSTALLED
HORIZONTALLY
Majestic • QUARTZ32, QUARTZ36 Installation Manual • 2412-980 Rev. H • 10/16
H
+ H
Maxi-
1
2
mum
V Minimum
ALL MODELS
90 Elbow *
1/2 ft. 152 mm
1/2 ft.*
152 mm
1 ft.
305 mm
1-1/2 ft.*
457 mm
2 ft.
610 mm
2-1/2 ft.*
762 mm
4 ft.
1.2 m
3-1/2 ft.
1.1 m
6 ft.
1.8 m
4-1/2 ft.
1.4 m
14 ft.
4.3 m
H + H
MAX. =14 ft. (4.3 m)
1
V + H + H
MAX. = 40 ft. (12.2 m)
1
* See warning below
H
1