Mantel And Wall Projections - Majestic fireplaces QUARTZ32IN Installation Manual

Quartz series
Table of Contents

Advertisement

B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.)
Note: Measurement is taken from top of the
opening, NOT the top of the fi replace.
Combustible Mantels
All measurements are in inches.
11
10
9
8
7
6
5
4
3
1
6
5
4
3
TOP OF HOOD OR
FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.2 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Non-Combustible Mantels
All measurements are in inches.
8
7
6
5
4
3
5
TOP OF HOOD OR
FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.3 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
54
CEILING
12
32
13
12
11
10
9
8
7
CEILING
12
11
10
9
32
13
12
11
10
9
8
7
6
Majestic • QUARTZ32, QUARTZ36 Installation Manual • 2412-980 Rev. H • 10/16
Combustible or Non-Combustible Mantel Legs
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Note: Clearance from opening
to perpendicular wall.
Figure 10.4 Mantel Leg (Acceptable on both sides of opening)
Combustible or Non-Combustible Wall Projections
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Note: Clearance from opening
to perpendicular wall.
Figure 10.5 Wall Projection (Acceptable on one side of opening)
1/2 IN.
MINIMUM
2-7/8 IN.
MINIMUM
3 FT. MAXIMUM
3 IN.
MINIMUM
5-7/8 IN.
MINIMUM
UNLIMITED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quartz32ilQuartz36inQuartz36il

Table of Contents