Top Vent - Vertical Termination - (continued)
Two 90º Elbows
Note: Use SLP Series
components only.
Figure 4.15
V
2
Majestic • QUARTZ32, QUARTZ36 Installation Manual • 2412-980 Rev. H • 10/16
90 Elbow
1-1/2 ft.
1/2 ft.
152 mm
1-1/2 ft. 457 mm
2-1/2 ft. 762 mm
3-1/2 ft.
1.1 m
4-1/2 ft.
1.4 m
H MAX. =15 ft. (4.6 m)
V
+ V
1
* No specifi c restrictions on this value EXCEPT V
exceed 40 ft. (12.2 m)
H
1
H MAX.
V
2
457 mm
*
2 ft.
610 mm
*
3 ft.
914 mm
*
5 ft.
1.5 m
*
7 ft.
2.1 m
*
15 ft.
4.6 m
*
+ H MAX. = 40 ft. (12.2 m)
2
+ V
1
Note: There MUST be a 25%
reduction in total H when
using fl ex vent except when
using the simple up and out
installation. See Figure 4.8.
V
1
V
+ V
MIN.
1
2
*
*
*
*
*
*
+ H cannot
2
23