Majestic fireplaces QUARTZ32IN Installation Manual page 19

Quartz series
Table of Contents

Advertisement

Top Vent - Horizontal Termination
One Elbow
One 90º Elbow
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when
using fl ex vent except when
using the simple up and out
installation. See Figure 4.8.
WARNING *
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fi replaces, a one foot minimum
vertical vent section is required before installing
fi rst elbow.
• When using DVP-TB1 termination cap on top vented
fi replaces, a three foot minimum vertical vent section is
required before installing fi rst elbow.
Figure 4.10
Majestic • QUARTZ32, QUARTZ36 Installation Manual • 2412-980 Rev. H • 10/16
1-1/2 ft.*
2-1/2 ft.*
H
1
H
Maximum
1
V
Minimum
1
ALL MODELS
90 Elbow *
18 in.
1/2 ft.*
152 mm
2 ft.
457 mm
3 ft.
762 mm
5 ft.
3-1/2 ft.
1.1 m
7 ft.
4-1/2 ft.
1.4 m
14 ft.
H MAX. =14 ft. (4.3 m)
V + H MAX. = 40 ft. (12.2 m)
* See warning below
V
1
457 mm
610 mm
914 mm
1.5 m
2.1 m
4.3 m
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quartz32ilQuartz36inQuartz36il