    WMC Series Woodburning Fireplace Homeowner's Installation and Operating Manual For Models: WMC36 WMC42 FP583A 12/18/98 For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. 20000583 4/07 Rev. 21...
  • Page 2: Table Of Contents

    fireplace surround. The WMC Series fireplaces are solid fuel, woodburn- Burn only solid wood fuel or gas logs. ing premium fireplaces. The WMC36/42 are circulating Do not install a solid fuel burning insert or other prod- models with removable grilles (louvers).
  • Page 3: Specifications And Framing

    WMC Series Woodburning Fireplace WMC36 Series Woodburning Fireplace — Circulating Model 22" (559mm) Rough Opening 47" (1194mm) Depth 11" Dia. ¹⁄₂" (13mm) (279mm) 8¹⁄ ₄ " 22¹⁄₂" (210mm) (572mm) 8" Dia. (203mm) 22" (559mm) Recessed ⁵⁄₈" (16mm) Nailing Flange Rough Opening Width 41"...
  • Page 4: Parts Identification

    WMC Series Woodburning Fireplace Front Width Back Width Depth WMC36 33¹⁄₂" 18¹⁄₄" 20¹⁄₄" (851 mm) (464 mm) (514 mm) WMC42 39⁵⁄₈" 18¹⁄₄" 15¹⁄₄" (1007 mm) (464 mm) (387 mm) FP1531 Fig. 2a Hearth dimensions. FP1531 Chase Installation hearth dimensions 9/04 djt...
  • Page 5: Chimney Requirements

    20 feet. (G from the hearth to the chimney exit. 81" 146" plus H cannot exceed 20 feet.) 84" 151¹⁄₄" WMC36 WMC42 E. A chimney support (Model SKCS8, 87" 156¹⁄₂" Maximum: TCS8A - 8 inch triple wall) is required 89¹⁄₄"...
  • Page 6: Planning Information

    WMC Series Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure The Ten Foot Rule safety and to save time and money. An installer must predetermine where a fireplace will be set and how the Major U.S. building codes specify a minimum chimney chimney system will be run.
  • Page 7: Installation

    WMC Series Woodburning Fireplace Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the Insulating Fireplace Enclosure hearth. Chimney supports are required if the vertical for Cold Climates height exceeds 30' (9 m) with SK8 chimneys or 20' (6 If you live in a cold climate, it is not required but m) with 3-wall chimneys.
  • Page 8 WMC Series Woodburning Fireplace Framing Ground Framing can be constructed before or after the fire- Ground Screw place is set in place, however, most installers build the frame before setting the fireplace. Black Variable Speed Con- Frame fireplace with 2 x 4 lumber or heavier materials. Wall trol (optional) Junction Box...
  • Page 9 Either chimney system may be used, Imaginary Cen- but must not be mixed. terpoint NOTE: To use the TWABR adapter on the WMC36, remove and discard the cover plate on the top shield. (Fig. Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9¹⁄₄"...
  • Page 10 WMC Series Woodburning Fireplace Framing the Ceiling Hole Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at Metal Safety Strips attic level.
  • Page 11 WMC Series Woodburning Fireplace Installing Outside Air Kit Inner Pipe Section An outside air kit is installed in all WMC Series Fire- Pipe places. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors).
  • Page 12 WMC Series Woodburning Fireplace Attic Installation Nails (4) Attic Insula- Firestop Spacer tion Shield Nails (4 required) Joist NOTE: If the attic insulation shield is used, the firestop is not required in the attic installation. Attic Joist Ceiling Installation Base Flanges Ceiling FP263...
  • Page 13 WMC Series Woodburning Fireplace Cut and Frame Roof Hole Air Space Clearances Size of roof hole varies with the type of chimney ter- Combustible framing material MUST NOT mination installed. Refer to installation instructions penetrate AIR SPACE (shaded areas). provided with the chimney termination to find correct size of roof hole.
  • Page 14 WMC Series Woodburning Fireplace used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace open- Combustible 12" Mantel and (305mm) Finished Wall ing to bottom of mantel shelf. Trim Max. All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must Header 1¹⁄₂"...
  • Page 15 INSULATION must overlap FLOOR Minimum height and width is 40" x 40". VALUE "R" ���" minimum ** Dimension/degree of angle will vary depending on thickness of noncombustible surround facing. WMC36 16" 12" 48° 41° 18" 14" 7³⁄₄" 16"...
  • Page 16 WMC Series Woodburning Fireplace COMMON MATERIALS AND FACTORS Wall Covering MINIMUM Noncombustible MATERIAL 2 x 4" Header - THICKNESS Decorative Do not notch at EH2416 Facing standoffs. 0.458 1.09 0.50 in.** (CFM Corporation) Seal all cracks between fireplace surround and wall Common Brick 0.10 5.46 in.**...
  • Page 17: Installing Line For Gas Log

    WMC Series Woodburning Fireplace Installing Line for Gas Logs Fireplace Top View Hole in Outer Casing CFM Corporation fireplaces are designed to accept a 1/2" gas line for installation of an approved gas appli- 1" ance. (CFM Corporation manufactures a wide variety Min.
  • Page 18: Replacement Parts

    WMC Series Woodburning Fireplace 17a,b CFM Corporation reserves the right to make changes in design, materials, specificaitons, prices and discontinue colors and products at any time, 2-583 without notice. Parts page WMC36/42 Woodburning Fireplace 3/2/99 djt Units: FE40C0, GE40C0 Item/Model Number WMC36 WMC42 1.
  • Page 19: Accessories

    36GDKS (WMC36) 42GDKS (WMC42) Outside Air Termination Completes connection from air kit to out-of-doors AK-MST Chimney Adapter Converts WMC36 to use 3-wall system TWABR Hearth Extension Insulation Provides hearth extension floor protection EH2416 Hearth Patch Compound Patch cracks in hearth...
  • Page 20 WMC Series Woodburning Fireplace Chimney Components U.S. Component Description Model Number Round Top Termination Top used to terminate chimney at roof. RLTSK8 (SK8) (Flashing not included.) Round Top Termination - Top used to terminate chimney at chase. RLTSK8L Extended (SK8) (Flashing not included.) Flashing Metal finishing required around Contemporary...
  • Page 21 WMC Series Woodburning Fireplace (Chimney Components con't.) Component Description Model Number Square Chase Termination Square chimney cap used to terminate chimney SLTS8 through chase. Includes adapter. (Flashing material) Adapter Kit Required to unite 3-wall chimney with S20BR, S20UB S20BT, S20BW Traditional Top Housing Chimney Support Used to support the chimney at each 30' of TCS8A...
  • Page 22 WMC Series Woodburning Fireplace 20000583...
  • Page 23 PRE-ENGINEERED Fireplace Systems ® the Fireplace, and operated at all times under normal condi- CFM Corporation warrants its MAJESTIC FIREPLACES® Pre- tions, use and service according to the operative instructions Engineered Fireplace (“Fireplace”) and the CFM Corporation furnished with the Fireplace, and only if and so long as the supplied firegrate, glass doors, outside air system, fan motor,...
  • Page 24 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com...