Technical Specifications; Power Supply Specifications - Siemens RUGGEDCOM RX1511 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1511:
Table of Contents

Advertisement

RUGGEDCOM RX1511
Installation Guide

Technical Specifications

The following sections provide important technical specifications related to the device and available modules:
Section 4.1, "Power Supply Specifications"
Section 4.2, "Failsafe Relay Specifications"
Section 4.3, "Copper Serial Port Specifications"
Section 4.4, "Copper Ethernet Port Specifications"
Section 4.5, "Fiber Optic Ethernet Port Specifications"
Section 4.6, "Cellular Modem Specifications"
Section 4.7, "Operating Environment"
Section 4.8, "RUGGEDCOM APE Specifications"
Section 4.9, "Mechanical Specifications"
Section 4.1

Power Supply Specifications

Power
Supply Type
HI
HIP
24
24P
48
48P
12
12P
a
Power consumption varies based on the device configuration. A typical RX1511 chassis will consume approximately 25 W of power.
b
Based on #16 AWG wiring.
c
(T) denotes time-delay fuse.
Power Supply Specifications
Input Range
Min
Max
88 VDC
300 VDC
85 VAC
264 VAC
88 VDC
300 VDC
85 VAC
264 VAC
13 VDC
36 VDC
36 VDC
72 VDC
9 VDC
15 VDC
Internal
Maximum Power
Fuse Rating
Consumption
c
3.15 A(T)
65 W
c
3.15 A(T)
65 W
c
10 A(T)
63.5 W
c
3.15 A(T)
60 W
12 A
67 W
Technical Specifications
Maximum
Insulation
a
b
Cable Length
2800 VDC
for 1 minute
9.4 m (30.8 ft)
1500 VDC
for 1 minute
45.5 m (149 ft)
1500 VAC or
5.5 m (18 ft)
2121 VDC
for 1 minute
Chapter 4
37

Advertisement

Table of Contents
loading

Table of Contents