Automation system, hardware and installation (228 pages)
Summary of Contents for Siemens RUGGEDCOM WIN5114-V
Page 1
Preface Introduction Installing the Subscriber Unit RUGGEDCOM WIN5114-V Device Management Technical Specifications Certification Installation Guide 10/2018 RC1310-EN-03...
Page 2
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Preface Preface This guide describes the RUGGEDCOM WIN5114-V. It describes the major features of the subscriber unit, installation, commissioning and important technical specifications. It is intended for use by subscriber unit installers and operators, and assumes readers have a working knowledge of WiMAX technologies and procedures.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
Introduction Introduction The RUGGEDCOM WIN5114-V subscriber unit is part of the RUGGEDCOM WIN family, a line of mobile WiMAX broadband wireless access systems based on the IEEE 802.16e mobile WiMAX standard. The RUGGEDCOM WIN5114-V is a high-performance, self-learning subscriber. It automatically detects the base station on the best signal available, allowing for plug-and-play installation and maintenance free operation.
The subscriber unit supports both IP convergence sublayer for wireless Internet service providers or Ethernet Convergence Sublayer, ideal for mission critical private networks. Section 1.2 Description The RUGGEDCOM WIN5114-V features various ports, controls and indicator LEDs on the bottom panel for connecting, configuring and troubleshooting the subscriber unit. RSSI W.LINK PWR Figure 1: RUGGEDCOM WIN5114-V...
Section 2.6, “Grounding the Subscriber Unit”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM WIN5114-V: Tools Greases • Wrench or socket set • Marine grease (for marine applications only) • Phillips screwdriver Tapes •...
WARNING! Safety hazard – risk of serious personal injury and/or damage to equipment. Installing the RUGGEDCOM WIN5114-V can pose a serious safety hazard. Be sure to take precautions to avoid the following: • Exposure to high voltage lines during installation •...
Chapter 2 RUGGEDCOM WIN5114-V Installing the Subscriber Unit Installation Guide IMPORTANT! This product should be installed in a restricted access location where access can only be gained by authorized personnel who have been informed of the restrictions and any precautions that must be taken.
Configure the subscriber unit. For more information, refer to Section 3.1, “Configuring the Subscriber Unit”. Section 2.2 Unpacking the Subscriber Unit The following items are included in the RUGGEDCOM WIN5114-V package: Item Quantity RUGGEDCOM WIN5114-V Subscriber Unit Radio Frequency (RF) antenna cables, 5 m (16.4 ft) long...
Do not attempt to touch or remove the component. Section 2.4 Mounting the Subscriber Unit The RUGGEDCOM WIN5114-V is designed for maximum mounting and display flexibility. It can be secured to a bracket and then mounted to a pole, wall or tower. NOTE For detailed dimensions of the subscriber unit, refer to Section 4.6, “Dimension...
RUGGEDCOM WIN5114-V Chapter 2 Installation Guide Installing the Subscriber Unit When choosing the mounting location for the unit, consider the available mounting structures and antenna clearance. Site Survey Most wireless networks include many subscriber/base stations installed in various locations in an overlapping radio-cell pattern.
Chapter 2 RUGGEDCOM WIN5114-V Installing the Subscriber Unit Installation Guide Figure 2: Mounting the Subscriber Unit to a Wall or Tower 1. Subscriber Unit 2. Mounting Kit 3. Wall Holder/Pole Mount 4. M8 × 25 mm Hex Screw 5. M8 Spring Washer 6. M8 Flat Washer 7. M8 Nut 8. M5 Flat Washer 9. NS 1/4" × 1/2" HEX Chipboard Screw 10. Wall Anchor Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets, washers and screws.
Page 17
RUGGEDCOM WIN5114-V Chapter 2 Installation Guide Installing the Subscriber Unit Attach the subscriber unit to the mounting bracket. Figure 3: Mounting the Subscriber Unit to a Large Pole 1. Subscriber Unit 2. Pole 3. Clamping Bracket 4. Mounting Bracket 5. M8-25 Hex Screw 6. M8 Spring Washer 7. M8 Flat Washer ...
14 N·m (10 lbf-ft). Section 2.5 Installing the Antennas The RUGGEDCOM WIN5114-V supports N-Connect female antennas. To install an antenna, do the following: WARNING! Radiation hazard – risk of Radio Frequency (RF) exposure. This subscriber unit is compliant with the requirements set forth in FCC CFR 47, section 1.1307, addressing Radio Frequency (RF) exposure from...
Switch-Mode Power Supplies (SMPS). Figure 5: Antenna and Lightning Protector Assembly 1. Drain Wire 2. RUGGEDCOM WIN5114-V 3. Shielded Coaxial Cable 4. Lightning Protector 5. Ground Wire 6. Antenna Make sure the PWR LED on the subscriber unit is on.
Section 2.7 Connecting Power and Data The RUGGEDCOM WIN5114-V requires a 9 to 36 VDC Class 2 power supply. IMPORTANT! When connecting a DC battery power supply, make sure to use a 36 VDC, 3 A, double-pole circuit breaker as the main disconnecting device.
RUGGEDCOM WIN5114-V Chapter 2 Installation Guide Installing the Subscriber Unit • Section 2.8.2, “Applying Cold Shrink Tubing” • Section 2.8.3, “Applying Self-Amalgamating Tape” Section 2.8.1 Weatherproofing a Cable To weatherproof a cable, do the following: IMPORTANT! PVC tape, silicon sealant and glue are not recommended for weatherproofing, as these materials are difficult to apply accurately and are difficult to remove.
Chapter 2 RUGGEDCOM WIN5114-V Installing the Subscriber Unit Installation Guide Section 2.8.3 Applying Self-Amalgamating Tape To apply self-amalgamating (or self-fusing) tape to a cable end, do the following: IMPORTANT! When applying self-amalgamating tape, make sure to stretch it to 2/3 of its original width to form a tight seal.
RUGGEDCOM WIN5114-V Chapter 3 Installation Guide Device Management Device Management This section describes how to connect to and manage the subscriber unit. CONTENTS • Section 3.1, “Configuring the Subscriber Unit” Section 3.1 Configuring the Subscriber Unit Once the subscriber unit is installed and connected to the network, it must be configured. The RUGGEDCOM WIN5114-V features a Web-based User Interface (UI) for all configuration management.
Section 4.4, “Operating Environment” • Section 4.5, “Mechanical Specifications” • Section 4.6, “Dimension Drawings” Section 4.1 Power Supply Requirements The RUGGEDCOM WIN5114-V requires an external power supply that meets the following requirements: Power Supply Type Class 2 Input Range 10 to 36 VDC Section 4.2 Power Consumption...
-20 to 100 dBm Dynamic Range (Transmitter) -20 to 27 dBm Section 4.4 Operating Environment The RUGGEDCOM WIN5114-V is rated to operate under the following environmental conditions. Ambient Operating -40 to 75 °C (-40 to 167 °F) Temperature Ambient Storage Temperature -40 to 75 °C (-40 to 167 °F)
RUGGEDCOM WIN5114-V Chapter 5 Installation Guide Certification Certification The RUGGEDCOM WIN5114-V ODU SU has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 5.1, “Approvals” • Section 5.2, “Environmental Type Tests”...
Mobile Operation in Licensed Bands Section 5.1.5 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Installation Guide Certification A copy of the Material Declaration is available online at https://support.industry.siemens.com/cs/ww/en/ view/109738831. Section 5.2 Environmental Type Tests The RUGGEDCOM WIN5114-V has passed the following environmental tests. Test Description Test Levels IEC 60068-2-1 Low Temperature -25 °C for 72 hours -40 °C (-40 °F) for 16 hours...
Page 32
Chapter 5 RUGGEDCOM WIN5114-V Certification Installation Guide Test Description Test Levels 100 shocks in each direction IEC 60068-2-32 Free Fall Height: 1 m (3.3 ft) Nebs: GR63 One fall on 3 faces, 3 edges and 4 corners IEC 60068-2-30 Humidity (Cycling) 30 °C (86 °F) @ 90 to 100% for 2 cycles...