SELECTING LOCATION
To determine the safest and most efficient
location for the fireplace, you must take into
consideration the following guidelines:
1. The location must allow for proper clear-
ances (see Figures 1 and 2).
2. Consider a location where the fireplace
will not be affected by drafts, air condition-
ing ducts, windows or doors.
3. A location that avoids the cutting of
joists or roof rafters will make installation
easier.
4. An outside air kit is available with this
fireplace (see Optional Outside Air Kit on
page 7).
MINIMUM CLEARANCE TO
COMBUSTIBLES
Ceiling
Back and sides of fireplace
Floor**
Perpendicular wall to opening 12" minimum
Top spacers
Mantel clearances
Chimney outer pipe surface
* Not required at nailing flanges
** See step 2 of Framing
WARNING: Do not pack re-
quired air spaces with insulation
or other materials.
Minimum/Maximum Chimney Height for
Residential Installation
The minimum height of the chimney, mea-
sured from the base of the fireplace to the flue
gas outlet of the termination, is 14.5 feet for
straight flue or a flue with one elbow set. The
maximum distance between elbows is 6 feet.
For systems with two elbow sets, the minimum
height is 22 feet. The maximum height of any
system is 50 feet. This measurement includes
the fireplace, chimney sections and the height
of the termination assembly at the level of
the flue gas outlet (see Figure 18, page 13).
4

FIREPLACE INSTALLATION

40" minimum
3/4" minimum*
0" minimum
0" minimum
see Mantels, 6
1" minimum
www.SuperiorFireplaces.US.com
Minimum/Maximum Chimney Height for
Outdoor Installation
The minimum height of the chimney, mea-
sured from the base of the fireplace to the
flue gas outlet of the termination, is 7
(minimum of 4 feet of chimney pipe sections
required for outdoor installation).
FRAMING
1. Frame opening for fireplace using the
dimensions shown in Figures 1 and 2.
2. If fireplace is to be installed directly on
carpeting, tile (other than ceramic) or any
combustible material other than wood
flooring, the fireplace must be installed
upon a metal or wood panel extending
the full width and depth of fireplace.
3. Set fireplace directly in front of this open-
ing and slide unit back until nailing flanges
touch side framing.
41.250"
Figure 1 - Framing Dimensions
52.183"
24.399"
Figure 2 - Corner Installation
WARNING: DO NOT
INSTALL IN SLEEPING
ROOM OF MOBILE
HOMES.
41.375"
21.875"
17.253"
MAINTAIN
CLEARANCE AT
SIDES AND BACK
OF FIREPLACE
3
/
" CLEARANCE
4
NOT REQUIRED AT
NAILING FLANGES
73.798"
127020-01A
/
feet
1
2
/
"
3
4