Superior WRE6842RS Installation And Operation Instruction Manual

Indoor/outdoor wood burning fireplace

Advertisement

Quick Links

P/N 127011-01 Rev. A 02/2014
P127011-01
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains
information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other
important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with
UL127 CAN/ULC-S610-M87 standard as a
FACTORY BUILT FIREPLACE.
f i r e - p a r t s . c o m
This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to
ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a
permit.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Superior
PFS
Models
®
C
US
SAVE THIS BOOK
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
POUR LE CANADA: L'autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l'installation afin de déterminer la
nécessité d'obtenir un permis.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
Indoor/Outdoor Wood Burning Fireplace
TM
WRE6842RS
WRE6842IS
WRE6842RH
WRE6842IH
WRE6850RS
WRE6850IS
WRE6850RH
WRE6850IH

Advertisement

Table of Contents
loading

Summary of Contents for Superior WRE6842RS

  • Page 1 Installation and Operation Instructions Superior Indoor/Outdoor Wood Burning Fireplace P/N 127011-01 Rev. A 02/2014 Models ® WRE6842RS WRE6850RS WRE6842IS WRE6850IS WRE6842RH WRE6850RH P127011-01 WRE6842IH WRE6850IH SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
  • Page 2 OWNER’S OPERATION AND INSTALLATION MANUAL INDOOR/OUTDOOR WOOD BURNING MASONRY FIREPLACES WITH INSULATION ® f i r e - p a r t s . c o m These models meet the EPA Wood Burning Fireplace Program Phase 2 emission level. NOTE: To ensure proper fireplace operation, the catalyst should be replaced at a minimum of 3 years and a maximum of 5 years.
  • Page 3: Table Of Contents

    WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified installer or local distributor. TABLE OF CONTENTS Safety ..............3 Glass Door Installation ........
  • Page 4: Specifications

    SPECIFICATIONS 42" MODELS f i r e - p a r t s . c o m " " " " 23" " (Ref.) 29" " " " 42" HEARTH " 5/8" OUTSIDE 11" ACCESS 58" 67" 61" GAS LINE 49"...
  • Page 5 SPECIFICATIONS Continued 50" MODELS f i r e - p a r t s . c o m " 24" " " 23" " (Ref.) " " " " " 50" HEARTH OUTSIDE 11" ACCESS 67" GAS LINE 58" 49" ACCESS 61"...
  • Page 6: Fireplace Installation

    FIREPLACE INSTALLATION FRAMING 1. Frame opening for fireplace using dimen- SELECTING LOCATION sions shown in Figures 2 and 3. To determine the safest and most efficient 2. If fireplace is to be installed directly on location for the fireplace, you must take into carpeting, tile (other than ceramic) or any consideration the following guidelines: combustible material other than wood...
  • Page 7 FIREPLACE INSTALLATION Continued MANTELS Note: For outdoor installations, fireplace enclosure must allow for adequate drainage A mantel may be installed if desired (see Figure and fresh air ventilation. It is recommended 6). Woodwork such as wood trims, mantels that a sealed, corrosion resistant catch pan or any other combustible material projecting with provision for drainage be installed under from front face must not be placed within 18"...
  • Page 8: Venting Installation

    VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT WARNING: The opening in (MODEL AK4/AK4F) the collar around the chimney at The installation of an outside air kit should the top of the fireplace must not be performed during the rough framing of be obstructed.
  • Page 9 VENTING INSTALLATION Continued Continue to assemble chimney sections as if properly locked. It is not necessary to add outlined above, making sure that both the screws to keep the chimney together (excep- inner and outer pipe sections are locked to- tion, see Figure 9).
  • Page 10 VENTING INSTALLATION Continued Return Return Elbow Elbow Return Offset Offset Elbow Elbow Elbow 6' Max. 6' Max. Ceiling Support Pipe Return 12S-12DM Return 6' Max. Elbow Elbow 6' Max. Offset Offset Elbow 6' Max. Elbow 6' Max. Offset Elbow Figure 11 - Typical Offset Terminations Screws or Staples FIRESTOP SPACERS (FS-10) Firestop...
  • Page 11 VENTING INSTALLATION Continued Installing Flashing on a Metal Roof 5. Add next sections of pipe until end When installing the flashing on a metal roof, penetrates roof line. Check to see that it is required that putty tape be used between proper clearances are maintained.
  • Page 12 VENTING INSTALLATION Continued Terminations/Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations. In 18" any case, refer to the installation instructions Min. supplied with the termination. Typ. CAUTION: Do not seal open- ings on the rooftop flashing. Fol- low the installation instructions provided with the termination 24"...
  • Page 13: Firebrick Wall Installation

    FIREBRICK WALL INSTALLATION 2. Install the left and right firebrick walls. IMPORTANT: Installation of brick There is a bracket with 2 tabs on the should be done after the fire- bottom of each firebrick wall. Angle the place is placed in a permanent wall into the fireplace opening and into location.
  • Page 14 FIREBRICK WALL INSTALLATION Continued GROUTING INSTRUCTIONS 4. Install the rear firebrick wall last. Place the wall face side down on the hearth with the Material provided: bottom of the wall toward the rear of the Bag of cement firebox and the top toward the front of the Bag of sand fireplace.
  • Page 15 FIREBRICK WALL INSTALLATION Continued INSTALLING SCREEN INSTALLING GRATE RETAINERS 1. Slide round end of screen rod into rings at 1. Place the provided grate retainers on the top of screen. Attach one push-on nut to end hearth as shown in Figure 25. The back of rod before attaching last ring of screen.
  • Page 16 OPTIONAL GAS LINE INSTALLATION Gas line hook up should be done by your WARNING: Do not operate an supplier or a qualified service person. unvented gas log set in this fire- Note: Before you proceed, make sure your place with the chimney removed. gas supply is turned off.
  • Page 17: Optional Gas Line Installation

    OPTIONAL GAS LINE INSTALLATION Continued If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which WARNING: When using a have been found to comply with the standard decorative vented gas log, the for unvented room heaters, ANSI Z21.11.2 are damper must be removed or to be installed in this fireplace.
  • Page 18 AIR DEFLECTOR AND GLASS DOOR INSTALLATION Continued INSTALLING GLASS DOORS Spring clips have been installed but some Top Door adjustments may be needed. Install the doors Frame using the following steps: Smoke 1. With bifold doors completely folded, insert Shelf bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making...
  • Page 19: Operation And Maintenance Guidelines

    OPERATION AND MAINTENANCE GUIDELINES GLASS DOORS Glass doors are optional with the fireplace. When fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 33). Doors Fully Closed A fireplace equipped with glass doors operates Fireplace Front much differently than a fireplace with an open...
  • Page 20: Purefire Emissions Control System

    PUREFIRE EMISSION CONTROL SYSTEM OPERATION This fireplace is equipped with a PureFire Emission Control System. The Catalytic The proper use of a wood burning fireplace Hood system reduces particulates emissions equipped with the catalyst will significantly in a wood burning fireplace to meet the EPA reduce the emissions that it produces.
  • Page 21 EPA PHASE 2 EMISSIONS LEVEL THIS MODEL Fireplaces with lower emissions produce less smoke when installed and operated properly. MANUFACTURER: INNOVATIVE HEARTH PRODUCTS, LLC MODEL NAME: WRE6842RS WRE6842IS WRE6842RH WRE6842IH PARTICLE EMISSIONS: 4.4 GRAMS/KG OF WOOD BURNED * EPA has determined, based on testing by an accredited independent laboratory and a certification of conformity by a nation ally recognized certification body, that this model qualifies at the Phase 2 emissions level for U.S.
  • Page 22: Technical Service

    TECHNICAL SERVICE You may have further questions about installa- When calling please have your model and se- tion, operation, or troubleshooting. If so, con- rial numbers of your fireplace ready. tact INNOVATIVE HEARTH PRODUCTS at You can also visit our web site at 1-800-655-2008.
  • Page 23: Parts

    PARTS 42" AND 50" SUPERIOR MODELS f i r e - p a r t s . c o m 16/17 www.SuperiorFireplaces.US.com 127011-01A...
  • Page 24 PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. PART NO. DESCRIPTION QTY. Face Assembly • • Firebox Bottom Assembly • • Firebox Bottom •...
  • Page 25 PARTS 42" AND 50" SUPERIOR MODELS Picture may vary from actual f i r e - p a r t s . c o m www.SuperiorFireplaces.US.com 127011-01A...
  • Page 26 PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. NO. PART NO. DESCRIPTION QTY. 1 125118-01 Left Leading Brick 50" Red • • 125118-03 Left Leading Brick 42"/50"...
  • Page 27: Accessories

    ACCESSORIES OPTIONAL OUTSIDE AIR KIT FOR BI-FOLD GLASS DOORS FLOOR INSTALLATION - AK4F BDMO42E - 42" Ebony BDMO42G - 42" Pewter BDMO42C - 42" Oiled Bronze BDMO50E - 50" Ebony BDMO50G - 50" Pewter BDMO50C - 50" Oiled Bronze f i r e - p a r t s . c o m 30°...
  • Page 28 ACCESSORIES Continued STORM COLLAR - SC2-1 ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch FIRESTOP SPACER - FS-10 f i r e - p a r t s . c o m SQUARE CHASE-TOP TERMINATION - STL-12D AND STL-12DMP BLACK ROUND TOP TERMINATIONS...
  • Page 29 IMPORTANT NOTICE Canadian code CAN/ULC-S610-M87 and NOTICE: The firebox canopy (hood) A manufactured shroud which other pertinent codes require stainless steel must not be modified or replaced with chimney for the installation of this fireplace. has been approved by a national a canopy that may be provided with A Cold Air Climate Kit is also required in the unvented decorative room heater.
  • Page 30 THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 31 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. f i r e - p a r t s . c o m www.SuperiorFireplaces.US.com 127011-01A...
  • Page 32 f i r e - p a r t s . c o m 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 127011-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P127011-01...

Table of Contents