Superior WRE3036WS Installation And Operation Instructions Manual

Residential and outdoor wood-burning fireplace

Advertisement

P/N 127020-01 Rev. A 02/2014
P127020-01
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains
information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other
important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with
UL127 CAN/ULC-S610-M87 standard as a
FACTORY BUILT FIREPLACE.
This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to
ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a
permit.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installation and Operation Instructions
Superior
Wood-Burning Fireplace
PFS
Models
®
C
US
WRE3036WS
SAVE THIS BOOK
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
POUR LE CANADA: L'autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l'installation afin de déterminer la
nécessité d'obtenir un permis.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
Residential and Outdoor
TM
WRE3036WH
WRE3036RS
WRE3036RH

Advertisement

Table of Contents
loading

Summary of Contents for Superior WRE3036WS

  • Page 1 Superior Residential and Outdoor Wood-Burning Fireplace P/N 127020-01 Rev. A 02/2014 Models ® WRE3036WS WRE3036WH WRE3036RS WRE3036RH P127020-01 SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..............2 Operation and Maintenance Guidelines .... 14 Specifications ............3 Technical Service..........15 Fireplace Installation..........4 Replacement Parts ..........15 Venting Installation ..........6 Parts ..............16 Optional Gas Line Installation......13 Accessories ............19 SAFETY WARNING: Improper WARNING: Do not install a...
  • Page 3: Specifications

    SPECIFICATIONS GAS LINE RIGHT SIDE KNOCK ELECTRICAL OUTS OUTLET 1" AIRSPACE TO COMBUSTIBLE MATERIAL 0" TO NO COMBUSTIBLE 9.125" 3.5" MATERIAL ON FACE SPACERS 7.092" 8.717" AIR KIT 11.217" KNOCK OUT LEFT SIDE GAS LINE KNOCK COMBUSTIBLE OUTS WALL BOARD 0.75"...
  • Page 4: Fireplace Installation

    FIREPLACE INSTALLATION Minimum/Maximum Chimney Height for SELECTING LOCATION Outdoor Installation To determine the safest and most efficient The minimum height of the chimney, mea- location for the fireplace, you must take into sured from the base of the fireplace to the consideration the following guidelines: flue gas outlet of the termination, is 7 feet...
  • Page 5: Hearth Extension

    FIREPLACE INSTALLATION Continued 4. Check the level of the fireplace and shim Thermal conductivity "K" of materials can be with sheet metal if necessary. obtained from the manufacturer or supplier of the noncombustible material. If the hearth ex- 5. Before securing fireplace to prepared tension is to be covered, use noncombustible framing, the ember protector (provided) material such as tile, slate, brick, concrete,...
  • Page 6: Venting Installation

    FIREPLACE INSTALLATION Continued Combustible Top View of Fireplace Material " Ref. FIREBOX Safe 8.0" Zone for 6" Projection of Ref. 33° 2" Max. 33° Combustible SAFE ZONE Materials 3.0" 3" Nom. Combustible Min. to " Max. 12" Min. Material Must Perpendicular Not Overlap Side Wall...
  • Page 7 VENTING INSTALLATION Continued CHIMNEY PIPE WARNING: The opening in The INNOVATIVE HEARTH PRODUCTS collar around chimney at top of chimney system consists of 12", 18", 24", 36" fireplace must not be obstruct- and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual ed.
  • Page 8 VENTING INSTALLATION Continued USING ELBOW OFFSETS (30E-8DM) 3. Maximum length of pipe between supports (return elbow or 12S-8DM) is 6' of angle 1. To achieve desired offset, you may install run. Maximum of two 6' angle run sections combinations of 12", 18", 24", 36" and 48" per chimney system (see Figure 7).
  • Page 9 VENTING INSTALLATION Continued FIRESTOP SPACERS (3600FS-8DM-1) Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe Screws passes through a framed opening into a living space above, the firestop must be placed onto...
  • Page 10 VENTING INSTALLATION Continued PENETRATING ROOF FLASHING INSTALLATION (V6F-8DM OR V12F-8DM) To maintain a 1" clearance to the pipe on a roof with a pitch, a rectangular opening must Determine the flashing to be used with the roof be cut. opening chart. Slide flashing over pipe until 1.
  • Page 11 VENTING INSTALLATION Continued Terminations/Spark Arrestor CHASE INSTALLATIONS The fireplace system must be terminated with Instructions for chase installations are the listed round top or chase terminations. In included with the chase style termination any case, refer to the installation instructions chosen.
  • Page 12: Foot Rule

    VENTING INSTALLATION Continued 10 FOOT RULE FINISHING FIREPLACE All flue gas outlet chimney terminations must Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, extend a minimum of 3 feet in height above the highest point where it passes through the roof etc.
  • Page 13: Optional Gas Line Installation

    OPTIONAL GAS LINE INSTALLATION Gas line hook up should be done by your WARNING: Do not operate an supplier or a qualified service person. unvented gas log set in this fire- Note: Before you proceed, make sure your gas supply is turned off. place with the chimney removed.
  • Page 14: Operation And Maintenance Guidelines

    OPTIONAL GAS LINE INSTALLATION Continued WARNING: If the fireplace WARNING: When using a has been used for wood burning, decorative vented gas log, the the firebox and chimney must be damper must be removed or cleaned of soot, creosote and permanently locked in the fully ashes be a qualified chimney open position and the glass doors...
  • Page 15: Technical Service

    OPERATION AND MAINTENANCE GUIDELINES Continued OUTSIDE AIR AND DAMPER HANDLE OPERATION Handle Keyway The damper handle, which opens and closes Slot the damper blade, is located in the upper front face of the fireplace. Pushing the handle into the left of the keyway slot will free the damper blade to automatically open.
  • Page 16: Parts

    PARTS WOOD BURNING FIREPLACE MODELS WRE3036WS, WRE3036WH, WRE3036RS AND WRE3036RH 37/38 www.SuperiorFireplaces.US.com 127020-01A...
  • Page 17 PARTS WOOD BURNING FIREPLACE MODELS WRE3036WS, WRE3036WH, WRE3036RS AND WRE3036RH This list contains replaceable parts used in your fireplace. When ordering parts, see Replace- ment Parts on page 15 of this manual. NO. PART NO. DESCRIPTION QTY. 106638-01 Insulation Pan...
  • Page 18 PARTS WOOD BURNING FIREPLACE MODELS WRE3036WS, WRE3036WH, WRE3036RS AND WRE3036RH Right Side Rear Bottom Front Bottom Left Side REFRACTORY BRICK NO. PART NO. DESCRIPTION QTY. 106658-03 Left Refractory, Textured White Brick • 108164-03 Left Refractory, Textured White Herringbone • 106658-02 Left Refractory, Textured Red Brick •...
  • Page 19: Accessories

    ACCESSORIES DOUBLE WALL PIPE 12-8DM 12-8HT 18-8DM 18-8HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT BI-FOLD GLASS DOOR BDO36 - Black BDO36B - Brushed Brass BDO36P - Platinum ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM 30°...
  • Page 20 ACCESSORIES Continued OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION - AK4 MESH ROUND TOP TERMINATIONS RT-8DM, RT-8HT, RTL-8DM AND RTL-8HT MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT-8DM, RTT-8HT, RTTL-8DM AND RTTL-8HT OUTSIDE AIR KIT FOR FLOOR INSTALLATION - AK4F ROUND TOP TERMINATIONS WITH LOUVERS RLT-8DM, RLT-8HT...
  • Page 21 IMPORTANT NOTICE Canadian code CAN/ULC-S610-M87 and NOTICE: The firebox canopy (hood) A manufactured shroud which other pertinent codes require stainless steel must not be modified or replaced with chimney for the installation of this fireplace. has been approved by a national a canopy that may be provided with A Cold Air Climate Kit is also required in the unvented decorative room heater.
  • Page 22: Year Limited Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 23 KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.SuperiorFireplaces.US.com 127020-01A...
  • Page 24 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 127020-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P127020-01...
  • Page 25 Installation and Operation Instructions Superior Residential and Outdoor Wood-Burning Fireplace Models: WRE3042WS WRE3042WH WRE3042RS WRE3042RH ® P127055-01 P/N 127055-01 Rev. D 10/2014 REPORT NO. 10-078 SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
  • Page 26 Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety .....................2 Please carefully read and follow all instructions in this manual. Pay Specifications .................4 special attention to all warnings and safety information. Fireplace Installation ..............5 Following these safety, care, and operation instructions will help Venting Installation ................7 ensure many years of dependable and enjoyable service from your Optional Gas Line Installation ............12...
  • Page 27: Safety

    SAFETY Continued WARNING: CONTINUED OVERFIRING CAN PER- WARNING: BURNING IMPROPER FUEL (I.E. MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. CHARCOAL) CAN RESULT IN CARBON MONOXIDE SOME EXAMPLES OF CONDITIONS THAT COULD POISONING, WHICH MAY LEAD TO DEATH! CAUSE OVERFIRING ARE: Carbon Monoxide Poisoning – Early signs of carbon monoxide poisoning resemble the flu with headaches, • BURNING QUANTITIES OF SCRAP LUMBER, PINE BRANCHES, PAPER OR CARDBOARD BOXES...
  • Page 28: Specifications

    SPECIFICATIONS PIPE 1" AIRSPACE TO COMBUSTIBLE GAS LINE MATERIAL KNOCK OUTS RIGHT SIDE ELECTRICAL OUTLET STARTER NO COMBUSTIBLE SECTION MATERIAL BELOW TOP SPACERS 0" TO NO COMBUSTIBLE TOP SPACERS " MATERIAL ON FACE " " " 12" AIR KIT COMBUSTIBLE KNOCK OUT WALL BOARD 3/4"...
  • Page 29: Fireplace Installation

    FIREPLACE INSTALLATION SELECTING LOCATION FRAMING To determine safest and most efficient location for fireplace, you 1. Frame opening for fireplace using dimensions shown in Figures must take into consideration the following guidelines: 1 and 2. 1. Location must allow for proper clearances (see Figures 1 and 2). Note: When the fireplace is framed, the header has to be turned 2.
  • Page 30 FIREPLACE INSTALLATION Continued DRAIN PAN (DP42) MANTELS For outdoor installations, the fireplace enclosure must allow for A mantel may be installed if desired (see Figures 4 and 5). Woodwork adequate drainage and fresh air ventilation. It is recommended that such as wood trims, mantels or any other combustible material a sealed, corrosion resistant catch pan with provision for drainage projecting from front face, must not be placed within 12"...
  • Page 31: Venting Installation

    VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F) WARNING: The opening in collar around chimney at top of fireplace must not be obstructed. Never use Installation of outside air kit should be performed during rough fram- ing of fireplace due to the nature of it's location. Outside combustion blown insulation to fill chimney enclosure air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).
  • Page 32 VENTING INSTALLATION Continued ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY USING ELBOW OFFSET 30E-12DMO-8DMR SYSTEM To clear overhead obstructions, you may offset your chimney system SS-8DM starter section must be installed first. using 30E-12DMO-8DMR 30° Offset/return elbow. Each double wall chimney section consists of a galvanized outer A section or sections of chimney may be used between offsets and pipe, a stainless steel inner flue pipe and a wire spacer.
  • Page 33 VENTING INSTALLATION Continued 30E-8DM 30E-8DM Return Elbow Return Elbow 30E-12DMO-8DMR Return Elbow 30E-8DM 30E-8DM Offset Elbow 6' Max. 6' Max. Offset Elbow Ceiling Support Pipe 6' Max. 30E-12DMO-8DMR 30E-12DMO-8DMR 12S-8DM Return Elbow Return Elbow 8 DM Pipe 6' Max. 8 DM Pipe Starter Starter Section...
  • Page 34 VENTING INSTALLATION Continued FIRESTOP SPACERS (3600FS-8DM-1) Minimum Measurements Firestop spacers are required at each point where chimney penetrates " a floor space. Their purpose is to establish and maintain required (48.3 cm) 30" clearance between chimney and combustible materials. When pipe 1"...
  • Page 35 VENTING INSTALLATION Continued CHASE INSTALLATIONS Storm Collar Installation (SC1) Place storm collar over pipe and slide down until it is snug against Instructions for chase installations are included with chase style ter- open edge of flashing (see Figure 14). Use SC1 for all round termina- mination chosen.
  • Page 36: Optional Gas Line Installation

    VENTING INSTALLATION Continued EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP MIN. HEIGHT OF 22 FT. (WITH 2 ELBOW SETS) MAX. HEIGHT OF 50 FT. MAX. HEIGHT 50 FT. (ANY SYSTEM) EFFECTIVE HEIGHT EFFECTIVE HEIGHT OF TERMINATION CAP OF TERMINATION CAP STARTER STARTER...
  • Page 37: Operation And Maintenance

    OPTIONAL GAS LINE INSTALLATION Continued OPERATION AND MAINTENANCE If you install a decorative gas appliance (vented gas log), decorative GLASS DOORS gas appliance must comply with the Standard for Decorative Gas Glass doors are optional with this fireplace. When fireplace is in Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI operation, doors must be fully opened or fully closed position only Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance...
  • Page 38: Replacement Parts

    OPERATION AND MAINTENANCE Continued REPLACEMENT PARTS Note: Use only original replacement parts. OUTSIDE AIR AND DAMPER HANDLE OPERATION This will protect your warranty coverage for parts replaced under The damper handle, which opens and closes the damper blade, is warranty. located in upper front face of fireplace.
  • Page 39: Parts

    PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS, WRE3042WH, WRE3042RS, WRE3042RH Right Side Rear Bottom Front Bottom Left Side REFRACTORY BRICK KEY NO. PART NO. DESCRIPTION QTY. 107812-03 Left Refractory, Textured White Brick • 108169-03 Left Refractory, Textured White Herringbone • 107812-02 Left Refractory, Textured Red Brick •...
  • Page 40 PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS, WRE3042WH, WRE3042RS, WRE3042RH MODEL NO. CATALOG NO. WRE3042WS F0453 WRE3042WH F0454 WRE3042RS F0455 WRE3042RH F0456 37/38 Superiorfireplaces.US.com 127055-01D...
  • Page 41 WOOD BURNING FIREPLACE MODELS: WRE3042WS(F0453), WRE3042WH(F0454), WRE3042RS(F0455), WRE3042RH(F0546) This list contains replaceable parts used in your fireplace. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. KEY NO.
  • Page 42: Accessories

    ACCESSORIES OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION - AK4 DOUBLE WALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ROOF FLASHING OUTSIDE AIR KIT FOR FLOOR INSTALLATION 0 TO 6/12 PITCH - V6F-8DM AK4F 6/12 TO 12/12 PITCH - V12F-8DM ANTI-DRAFT SHIELD (Round Top Termination Only) MESH ROUND TOP TERMINATIONS...
  • Page 43 ACCESSORIES Continued 38FST FIRESTOP THIMBLE 8" FST30 FIRESTOP THIMBLE,8",30 DEGREES IMPORTANT NOTICE Canadian code CAN/ULC-S610-M87 and NOTICE: The firebox canopy (hood) A manufactured shroud which other pertinent codes require stainless steel must not be modified or replaced with chimney for the installation of this fireplace. has been approved by a national a canopy that may be provided with A Cold Air Climate Kit is also required in...
  • Page 44 Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. P127055-01 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 1-800-655-2008 Printed in U.S.A.

Table of Contents