WARNING: The opening in
collar around chimney at top of
fireplace must not be obstruct-
ed. Never use blown insulation
to fill chimney enclosure.
12
/
" Galvanized
3
8
Outer Pipe
8" Stainless
Inner Pipe
LINEAL GAIN
PART NO.
DESCRIPTION
36"
12-8DM
Pipe Section
12-8HT
18-8DM
Pipe Section
18-8HT
24-8DM
Pipe Section
24-8HT
36-8DM
Pipe Section
36-8HT
48-8DM
Pipe Section
48-8HT
RT-8DM
Round Termination
RTL-8DM Round Termination
Round Termination
RTT-8DM
with Slip Section
Round Termination
RTTL-8DM
with Slip Section
ET-8DM
Square Chase-Top
Square Chase-Top
ETO-8DM
Square Chase-Top
ETL-8DM
with Slip Section
Square Chase-Top
ETLO-8DM
with Mesh & Slip
* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.
Figure 6 - Lineal Gain
127020-01A
VENTING INSTALLATION
Hemmed
End
Fireplace
10
16
23
34
46
6
7
6
23
8
21
with Mesh
7" to 15"*
12" to
25
Section
www.SuperiorFireplaces.US.com
Continued
CHIMNEY PIPE
The INNOVATIVE HEARTH PRODUCTS
chimney system consists of 12", 18", 24", 36"
and 48" snap-lock, double-wall pipe segments,
planned for maximum adaptability to individual
site requirements. Actual lengths gained after
fitting overlaps must be taken into consider-
ation (lineal gain) and are given in the lineal
gain chart (see Figure 6). Lineal gain is the
actual measurable length of a part after two or
more parts are connected. For Canada, use
chimney parts designated "HT".
ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists
of a galvanized outer pipe, a stainless steel
inner flue pipe and a wire spacer. The pipe
GAIN
sections must be assembled independently
40"
as the chimney is installed.
/
"
5
When connecting chimney directly to the
8
fireplace, the inner flue pipe section must
/
"
be installed first with the lanced side up.
5
8
The outer pipe section can then be installed
over the flue pipe section with the hemmed
/
"
5
8
end up. Press down on each pipe section
until the lances securely engage the hem
/
"
5
8
on the fireplace starter. The wire will assure
the proper spacing between the inner and
/
"
5
8
outer pipe sections. Continue to assemble
" *
chimney sections as outlined, making sure
/
7
8
" *
that both the inner and outer pipe sections are
/
3
4
locked together. When installing double wall
/
" to
7
8
snap-lock chimney together, it is important to
/
"*
1
8
assure the joint between the chimney sections
/
" to
1
2
is locked. Check by pulling chimney upward
/
"*
1
2
after locking. The chimney will not come apart
12" *
if properly locked. It is not necessary to add
12" *
screws to keep the chimney together (excep-
tion - see Figure 9, page 10).
/
"*