Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
An French manual is available upon request. Order P/N 900088-00.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro
de la pièce 900088-00.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fi tted with
an adjustable safety gate or barrier screen.
C
US
WARNING
Listed to standards:
ULC-S610 and UL-127
Report # 14-199
EPA Cert. No. 537
P900087-00
INSTALLATION AND

OPERATION INSTRUCTIONS

WCT6820WS
EPA Wood-Burning Fireplace
P/N 900087-00 REV. E 06/2016
MODEL
WCT6820WS
This installation manual will enable you to obtain a safe, effi cient
and dependable installation of your fi replace system. Please read
and understand these instructions before beginning your installation.
Do not alter or modify the fi replace or its components under any cir-
cumstances. Any modifi cation or alteration of the fi replace system,
including but not limited to the fi replace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IHP wood-burning fi replaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
WARNING
• The fi replace cannot be operated without a door
or fi rescreen. Consult your dealer to select the
correct replacement door or fi rescreen.
• The fi replace is equipped with a blower, electri-
cal connection must be made prior to fi replace
installation
• Important! To assure proper alignment of glass
doors: Install this fi replace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fi replace only as described in these
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Superior WCT6820WS

  • Page 1: Operation Instructions

    INSTALLATION AND OPERATION INSTRUCTIONS WCT6820WS EPA Wood-Burning Fireplace P/N 900087-00 REV. E 06/2016 MODEL WCT6820WS This installation manual will enable you to obtain a safe, effi cient and dependable installation of your fi replace system. Please read and understand these instructions before beginning your installation.
  • Page 2: Safety Rules And Specifi Cations For Mobile Or Manufactured Home Installation

    WARNING can block the entrance of air. combustible flowing window treatments such as curtains on The WCT6820WS fi replace must nearby windows that are of suf- IMPORTANT be installed with an outside air fi cient length to be blown in front kit intake, which is included with of an open fl...
  • Page 3: Table Of Contents

    Dealing With A Chimney Fire .....Page 5 depending on the climate. Wood that is packed • The WCT6820WS fi replace is NOT intended Finish Door Casing Care ....Page 7 tight together will take longer to dry. Seasoned for use with a gas log set. Do not use a Disposing of Ashes ......Page 7...
  • Page 4: Starting And Maintaining A Fire

    10 to 20 minutes least amount of creosote on the glass and after reloading, depending on the heat and on There is no fl ue damper in the WCT6820WS in the chimney. The combustion air control the moisture content of the wood.
  • Page 5: Important Cautions

    H. Do not burn wood in the area in front of the a year during the heating season to determine When operating the WCT6820WS fi replace, grate. when a creosote buildup has occurred.
  • Page 6: Finish Door Casing Care

    Prohibited Fuels Top Baffl e Removal Prior to Cleaning The Achieving Clean Burns Chimney Check the exhaust in about 15 to 20 minutes This heater is designed to burn natural wood (see below). Large amounts of smoke indicate only. Higher effi ciencies and lower emissions Before starting to clean your chimney, we an improper burn setting (either too high or too generally result when burning air dried seasoned...
  • Page 7: Refractory Installation

    DOOR INSTALLATION The intense heat of the fi re will normally cause The door must be installed only when the installation of the WCT6820WS fi replace is completed. hairline cracks in the refractory. These cracks All you have to do is fi t the male part of the hinge, already on the door, to the female part, which can be minimized by proper curing as described is on the fi...
  • Page 8: Facade Installation

    fi replace. 12" MAX. (305mm) Hearth Extension Requirements Area where wood The WCT6820WS fi replace may be installed Mantel can be Mantel directly on a combustible fl oor. The supplied installed safety metal strip must be positioned as follows: One half under the front of the fi...
  • Page 9: Framing Dimensions

    Back Wall of Chase/Enclosure OUTSIDE CHASE Including Finising Materials if any FRAMING DIMENSIONS Corner Installation Fireplace Opening Width 19-5/8” 36-1/4” 921 mm 42” 1067 mm * Zero Clearance From Back 30-1/8” 764 mm Spacer to Wall 13-1/2” 343 mm 77” 1956 mm 37-1/2”...
  • Page 10: Nailing Flanges

    INSULATED CHASE CONSTRUCTION Storm Collar Roof Support Flashing Attic Radiation Shield Floor Ceiling NOTE: It is recommended that the Wall chase walls and fl oor be insulated in the same manner, using the same insulation, as the rest of the building, below the attic.
  • Page 11: Fireplace Blower

    Maximum length See Figure 14 Figure 15 Noncombustible Facing * The height of the louver must be measured from the base of the WCT6820WS fi replace to When installing the double outlet system, the the middle point of the louver. Drywall hot air outlets can be installed in the same room as the fi...
  • Page 12: Outside Air Kit

    OUTSIDE AIR KIT It is mandatory to install an outside air connec- Rain Cap tion to the WCT6820WS wood burning fi replace. The following components are required and are included with the fi replace: Flashing Collar Flashing • Outside air kit (includes 4 inch fl ex that goes...
  • Page 13: Chimney System

    fl ow reversal. outside chase installations. However, it is recommended for safety and 3. The IHP fi replace model WCT6820WS may be installed only with the reduction of heat loss. Security Chimneys International 6” diameter chimney systems DuraVent model DuraTech ®...
  • Page 14: Chimney Installation Instructions

    CHIMNEY INSTALLATION Attic Radiation Shield INSTRUCTIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, fl oor Solid Packed Pipe * Flashing and roof where the chimney will pass (see Figure 21). Use a plumb-bob to line up the center of the holes.
  • Page 15: Offset Chimney Installation

    3. Use another elbow to turn the chimney Minimum Chimney Height Using Elbows vertically. Lock it to the chimney. Fasten the straps attached to the elbow to the Fireplace Model WCT6820WS surrounding framing using nails or drywall Chimney Model ASHT+ / S2100+...
  • Page 16 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 17: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD OFFSET CHIMNEY INSTALLATION When traversing a combustible wall with the chimney at a 30º or 45º Chimney AC angle, an angled fi restop or wall radiation shield must be installed. Only one is required. RSMI45 / 6DTC-S45 NOTE: 45º...
  • Page 18: Glass Care - Replacement

    To cutting fl oor or roof joists (see fi replace dimen- The glass used for the WCT6820WS fi replace replace the gasket, fi rst remove all of the old sions Page 9).
  • Page 19: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) This support has three possible uses: 18” (460 mm) 1. For ASHT+ / HT6103+ S-2100+ / HT6000+ and DuraTech ® DTC**, it must be used on a roof to support the chimney. 2.
  • Page 20: Masonry Application Instructions

    Follow these steps: INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION WARNING: Before starting the installation, the masonry chimney 1- Position the fi replace in its location. Temporarily install the ASHT+ must be inspected by a qualifi ed chimney sweep. elbow on the top of the fi replace and, using a level, mark with an oval the location where the fl...
  • Page 21: Installation Accessories

    Central Forced Air Kit Accessories WCT6820WS Facade Black, BTCEFBK BTCEFBK Central Forced Air Kit, Central forced air kit including: blower WCT6820WS Facade Gold Plated, BTCEFG BTCEFG (BISZY), fl ex adaptor (BISAF), 2 clamps, variable speed WCT6820WS Facade Brushed Nickel, BTCEFBN BTCEFBN control (VRUW), thermo-disk (VTU), fan to fl...
  • Page 22: Replacement Parts

    REPLACEMENT PARTS LIST SPECIFICATIONS WCT6820WS Replacement Parts Cat. No. Model Description Part/Cat. No. F1792 WCT6820WS Blower (heat activated on/off pre-wired), UZY5 UZY5 Blower motor speed control (wall mount), VRUW VRUW EPA Estimated Model Emission Rate Heat Output Effi ciency Snap Disc, Blower WCT6820WS 3.7 g/hr...
  • Page 23: Chimney Components Lists

    6DTC-F12 Storm Collar Storm Collar 6DTC-SC NOTES: Fireplace Model WCT6820WS - Approved Venting Components manu-   N ova Temp HT6000+ is equivalent to Secure Temp S-2100+ factured by Security Chimneys International™ only.   N ova Temp HT6103+ and DuraTech ®...
  • Page 24 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 Tubinox® LL Chimney Lining System** 2125 Monterey, Laval, Quebec 1-800-361-4909 (USA) Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6”...
  • Page 25: Warranty

    Brand Wood-Burning Fireplace 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior ® Brand wood burning fi replace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, fi rebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 26: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fi replace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.

This manual is also suitable for:

Wrt4820ws

Table of Contents