Ariston Genius he 24 Installation And Servicing Instrucnions page 63

Gas fires condensing wall hung combination boilers
Table of Contents

Advertisement

MAINTENANCE GUIDE
MAINTENANCE GUIDE: GENUS HE
Fan
Maintenance Interval: Annually
How : Visual inspection / Clean as necessary
Primary Heat exchanger
Maintenance Interval: Annually
How : Visual inspection / Clean as necessary
Condensate trap
Maintenance Interval: Annually
or after cleaning primary heat exchanger
How : Visual inspection / Clean as necessary /
Add water before replacing
Pump
Maintenance Interval: At the first ignition and annually
How: Check that the AAV is open /
Visual inspection / Clean as necessary
63