Ariston Genius he 24 Installation And Servicing Instrucnions page 59

Gas fires condensing wall hung combination boilers
Table of Contents

Advertisement

MAINTENANCE GUIDE: GENUS HE
4.3
BURNER
Tools
1
Remove the silencer
2
Remove the three screws to free
the burner door
1. Stainless Steel Burner
2. Ignition electrode
3. Detection electrode
Page. 20 of 24
Supplied By www.heating spares.co Tel. 0161 620 6677
BURNER
Isolate the gas supply. Remove the
four screws and disconnect the
gas pipe from the gas valve
Pull the burner toward you.
Replace any gaskets that are damaged or showing signs of
Power
24 KW
30 KW
38 KW
MAINTENANCE GUIDE
Time
Pull the assembly towards
you
deterioration
2
3
Length
Venturi
104.6 mm
Ø 42 mm
135.8 mm
/
167 mm
/
15 min