2-8. CCP-8000 Panel Cabling
(3) Fix the bottom plate of the adaptor cases at the loca-
tions shown in the illustration using the 4 connecting
screws (BV3 x 10) and the 2 pieces of the connecting
plate B for every 2 pieces of adaptor case.
n
When the Vertical connection (A) is selected, there are
several locations where the connecting plate B cannot
be fixed. It makes no problems.
BV3 x 10
Adaptor cases
5. Install the side panel.
n
The screw positions that fix the side panel are different
in the connection methods (A), (B) and (C) respective-
ly. (see Fig. 2)
6. Install the operation module and fix it by tightening
the four screws on the sides.
2-24
BV3 x 10
Connecting plate B
7. For the connection methods (A) and (B) (see Fig. 2),
install the caps (L) and (R), and the module cover in
the direction of the arrow.
BV3 x 10
Cap (L)
For the connection method (C) (see Fig. 2), remove the
four stepped screws and install the panel covers (L)
and (R).
Panel cover (L)
Stepped screws M3
Module covers
Cap (R)
BV3 x 10
Panel cover (R)
Stepped screws M3