Soleus Air WM1-06E-01 Operating Instructions Manual

Soleus Air WM1-06E-01 Operating Instructions Manual

Electronic window air conditioners
Hide thumbs Also See for WM1-06E-01:

Advertisement

ModelV
:0(
6,400 BTU
:0(
8,500 BTU
:0(
10,200 BTU
(OHFWURQLF Window Air Conditioner
2SHUDWLQJ ,QVWUXFWLRQV

Advertisement

Table of Contents
loading

Summary of Contents for Soleus Air WM1-06E-01

  • Page 1 ModelV :0( 6,400 BTU :0( 8,500 BTU :0( 10,200 BTU (OHFWURQLF Window Air Conditioner 2SHUDWLQJ ,QVWUXFWLRQV...
  • Page 2 Thank you for choosing a Soleus Air Air Conditioner. This owner’s manual will SURYLGH \RX ZLWK valuable information necessary for the proper care and maintenance of your new SURGXFW 3OHDVH WDNH a few moments to thoroughly read the instructions and familiarize yourself with DOO WKH RSHUDWLRQDO aspects of your new air conditioner.
  • Page 3: Lcdi Power Cord And Plug

    ZLOO WXUQ RQ DJDLQ If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
  • Page 4 3$57 /,67 Top Mounting Rail Air Conditioner 2 AAA Remote Control Batteries Owner's Manual Foam Seal Top Mounting Rail Weather Insulation Board Insert Strip Curtain Curtain Lock Long Screw Short Screw Sash Lock Part List: Sash Lock (2) Window Air Conditioner (1) Foam Seal (1) Remote Control (1) Long Screw for Window Locking Bracket &...
  • Page 5 63(&,),&$7,216 Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. Power consumption is measured when the fan runs at the highest speed setting. These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. 0RGHO :0( :0(...
  • Page 6 Avoid fire hazard or electronic shock, WARNING: DO NOT use an extension cord or an adapter plug. DO NOT remove any prong from the power cord. DO NOT under any circumstances, cut, remove, or bypass the grounding prong!! Power supply cord with 3-prong grounding plug and current detection device ',6&/$,0(5 $// ,1)250$7,21 $1' 7+( 7(&+1,&$/ 63(&,),...
  • Page 7 Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made to fit inside a standard double-hung window. Make sure the window is in good shape and able to firmly hold the needed screws. If not, make repairs prior to installing the unit. WM1-06E-01 WM1-08E-01 / WM1-10E-01 Model Unit Height 12 5/8"...
  • Page 8 723 5$,/ ,167$//$7,21 NOTE: Top Rail and the side Panels are offset to provide the proper pitch to the rear of (5/16”). This is necessary IRU proper condensation utilization and drainage. If you are not using the side panels, the rear pitch must still be mainWDLQHG Attach the top rail onto the top of the outer case using four 6KRUW 6crews.
  • Page 9 ASSEMBLY & INSTALLATION (CONT.) Placing the Unit Inside a Normal Window Curtain & Weather Insulation Board Installa- tion 1. Set the unit in the window so that is centered. Place the unit so that from edge of the bottom rail is against NOTE: The Weather Installation Board adds an extra layer of the back edge of the sill.
  • Page 10 $66(0%/< ,167$//$7,21 &217 ,) $& LV %ORFNHG E\ D 6WRUP :LQGRZ 5HPRYLQJ WKH $LU &RQGLWLRQHU IURP WKH :LQGRZ A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. 1.
  • Page 11 USING YOUR AIR CONDITIONER Electronic Control Panel & Remote Control 4. Timer Set: Use these buttons on the control Note: This control panel display always shows the room panel and remote control to set the timer. Each temperature in Fan Mode except when setting the tem- press of the▲or▼...
  • Page 12 OPERATING THE UNIT USING THE REMOTE CONTRO/ /&' 'LVSOD\ MODE SLEEP ENERGY HIGH SAVER TIMER C/ F CHILD MYTEMP MODE LOCK Battery Size: AAA - NOTE: Do not mix old and new batteries or different types of AAA batteries.
  • Page 13 REMOTE CONTROL OPERATING INSTRUCTIONS 1. ON/OFF - Press the button to turn the A/C on or off. When the unit is turned off, the Timer function will be cancelled. The set temperature will be saved. 2. MODE SELECTION - Press the MODE button repeatedly to cycle between the different modes: Auto, Cool, Dry (Dehumidifier), and Fan.
  • Page 14 USING YOUR AIR CONDITIONER 5. Fan Only Mode: Use Fan Only mode at High, 1. Freezing Conditions: This is a cooling only air Medium, or Low fan speed to provide air circula- conditioner. It is not designed for freezing outdoor tion and filtering without cooling.
  • Page 15 &DELQHW &OHDQLQJ &$5( $1' &/($1,1* To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of $LU )LOWHU &OHDQLQJ the air conditioner may be dusted with an oil- The air filter should be checked at least once...
  • Page 16 7528%/(6+227,1* 352%/(0 3266,%/( &$86(6 62/87,216 The air conditioner is unplugged 7KH $LU &RQGLWLRQHU ZLOO QRW VWDUW Make sure the air conditioner plug LV pushed completely into WKH outlet Check the PDLQ fuse/circuit The fuse is blown/circuit breaker is breaker box and replace the fuse tripped.
  • Page 17 7528%/(6+227,1* &217 352%/(0 3266,%/( &$86(6 62/87,216 Hot and Humid weather. :DWHU LV GULSSLQJ RXWVLGH This is normal :DWHU LV GULSSLQJ LQVLGH WKH URRP The air conditioner is not correctly For proper water drainage, make tilted outside. sure the air conditioner is slightly tilted downward from the front of the unit to the rear.
  • Page 18 Five Year Compressor Limited Warranty Soleus Home Comfort warrants the accompanying Soleus Air Window Air Conditioner to be free of defects in ma- terial and workmanship for the applications specified in its operation instruction for a period of TWO (2) years from the date of original retail purchase in the United States.