INSTALLATION INSTRUCTION
TEMPERATURE CONTROL CHANGE-OUT - GDM AND T-SERIES
Installing The New Control
REQUIRED TOOLS
• Permagum
• Phillips Head Screwdriver
• Hex Head Driver
____________ STEP 1 ____________
Insert the control bulb into the copper
sleeve. Before insertion, be sure there are
no kinks in line. (figure 2)
____________ STEP 2 ____________
IMPORTANT!
Seal the end of the sleeve with permagum
to keep moisture out. (figure 3)
____________ STEP 3 ____________
Connect the two wires to the new tem-
perature control.
____________ STEP 4 ____________
Fasten the control onto the mounting plate
with two screws. Item A.
____________ STEP 5 ____________
Fasten the mounting plate to the cooler
with two screws. Item B.
____________ STEP 6 ____________
Replace black control knob and turn the
control to the #5 setting.
____________ STEP 7 ____________
Plug the Cooler in.
NOTE:
If it becomes necessary to remove the
housing be sure to tape off any interior
panel at risk of being scratched.
49
Copper
Sleeve
Permagum
Figure 3.
CAUTION
Wait at least 12 hours before
re-adjusting control. This allows the
Cooler to stabilize cycle.
Figure 2.
Control
Bulb