2.2

Cable Fabrication

Power cable
This echo sounder is designed to be powered with 12-24 VDC. Use the cable DPYCY-1.5 (Japan
Industry Standard) or equivalent.
6
Crimp-on lug
FV2-M4
Transducer cable
Separate the transducer cable well away from power cables to prevent interference. Connect the
cable to the transducer port (for high frequency and/or low frequency) at the rear of the display
unit. Fabricate the cable as below.
6
Attach WAGO
connector.
(See next page.)
[Composite transducer]
Approx. 70
Sheath
Vinyl tape
Clamp armor with cable clamp.
Approx. 100
Shield
Extract cores from here and cut inner materials.
Shield
Vinyl tape
30
Wrap shield around sheath 30 mm and cut
excess shield. Clamp here with cable clamp.
BLK, RED: L side
BLU, GRN: H side
3
30
Armor
Sheath
Sheath
Vinyl tape
Note: Never connect the shield to #2 of
the WAGO connector.
4
DPYCY-1.5
Armor
Sheath
Conductor
=
13.7 mm
S = 1.5 mm
= 1.56 mm
(AWG16)
2