# rpm -ivh hp_qla2x00- version-revision.architecture .rpm

Verifying virtual disks from the host

To ensure that the LUN is recognized after a virtual disk is presented to the host, do one of two things:
Reboot the host
Enter the /opt/hp/hp_fibreutils/hp_rescan -a command
To verify that the host can access the virtual disks, enter the # more /proc/scsi/scsi command.
The output lists all SCSI devices detected by the server. An EVA4400 LUN entry looks similar to the
following:
Host: scsi3 Channel: 00 ID: 00 Lun: 01
Vendor: HP
Type: Direct-Access

Novell NetWare

Driver files and parameters

The software kit that is included with the FCA contains the latest version of the FCA software files as
of the time of shipment. Software files are updated periodically and can be downloaded from the
following website: http://h20000.www2.hp.com/bizsupport/.
You can load the QL2x00.HAM driver with optional switches to modify driver functionality. Command
examples for both single path and multiple path are:
Single Path:
Load QL2x00.HAM Slot=2/Luns/allpaths/Portnames/startunit
Multiple Path:
Load QL2x00.Ham Slot=2/luns/allpaths/portnames

Installing Novell NetWare drivers

NOTE:
The QL2x00 HAM driver may not be compatible with NetWare versions earlier than 6.x.
To install the NetWare driver in a previously installed Netware 6.x system:
1.
Enter the following command from the console screen:
LOAD HDETECT
2.
Select Continue from the Options menu, and then press Enter.
3.
Select Modify from the Options menu, and then press Enter.
4.
Press Enter to Select and View with the drivers highlighted.
5.
Select Modify in the Additional Driver Options menu and press Enter.
6.
Press Insert or INS on your keyboard to add a new driver.
Model: HSV300
HP StorageWorks 4400 Enterprise Virtual Array installation guide