Verifying The Host Recognizes Array Devices - HP XP1024 System Configuration Manual

Disk array xp operating system configuration guide: windows 2000/2003
Hide thumbs Also See for XP1024:
Table of Contents

Advertisement

For details see the LUN Configuration and Security Manager User's Guide or Command
View XP Advanced Edition Device Manager Web Client User's Guide. Note the LUNS
and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and
device configuration.
NOTE:
A LUN assigned a number greater than FF is outside the accepted range of numbers
for a Windows server (00 to FE) and will not be recognized by the server or be
visible for use.
Windows 2003:
Miniport Driver. This is not necessary if using the StarPort Miniport Driver.
Windows 2000:

Verifying the host recognizes array devices

1.
Log into the host as an administrator.
2.
Right-click on the My Computer desktop icon, and click Manage.
3.
Click Device Manager.
4.
Click SCSI and RAID Controllers.
5.
Click the host bus adapter to open it, and verify all devices are displayed.
6.
Click each device, click Properties, and then click Settings.
7.
Record the device information on the worksheet in Appendix A.
To see LUNs, you must create a LUN 0 when using the ScsiPort
A LUN 0 must be created to discover more than LUNs 0 to 7.
Disk Array XP operating system configuration guide: Windows 2000/2003
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp12000Xp10000Xp128

Table of Contents