Configuring Emulex Fcas With The Lpfc Driver - HP StorageWorks 4400 Installation Manual

Enterprise virtual array
Hide thumbs Also See for StorageWorks 4400:
Table of Contents

Advertisement

For Solaris 8/9, install the latest Sun StorEdge SAN software with associated patches. To automate
the installation, use the Sun-supplied install script available at:
http://www.sun.com/download/
1.
Under Systems Administration, select Storage Management.
2.
Under Browse Products, select StorageTek SAN 4.4.
3.
Reboot the host after the required software/patches have been installed. No further activity
is required after adding any new LUNs once the array ports have been configured with the
cfgadm –c command for Solaris 8/9.
Examples for two FCAs:
cfgadm -c configure c3
cfgadm -c configure c4
For Solaris 10, use the Sun Update Manager to install the latest patches (see
service/sunupdate/). Reboot the host once the required software/patches have been installed.
No further activity is required after adding any new LUNs, as the controller and LUN recognition
is automatic for Solaris 10.

Configuring Emulex FCAs with the lpfc driver

To determine which Emulex FCAs and which driver version HP supports with the lpfc driver, see the
latest HP StorageWorks 4400 Enterprise Virtual Array release notes or contact your HP representative.
To configure Emulex FCAs with the lpfc driver:
Ensure that you have the latest supported version of the lpfc driver (see http://www.emulex.com).
Edit the following parameters in the /kernel/drv/lpfc.conf driver configuration file to set
up the FCAs for a SAN infrastructure:
topology=2;
scan-down=0;
nodev-tmo=60;
linkdown-tmo=60;
If using a single FCA and no multipathing, edit the following parameter to reduce the risk of data
loss in case of a controller reboot:
nodev-tmo=120;
If using Veritas Volume Manager (VxVM) DMP for multipathing (single or multiple FCAs), edit the
following parameter to ensure proper VxVM behavior:
no-device-delay=0;
In a fabric topology, you use persistent bindings to bind a SCSI target ID to the world wide port
name (WWPN) of an array port. This ensures that the SCSI target IDs remain the same when the
system reboots. You set persistent bindings by editing the configuration file or by using the lputil
utility.
NOTE:
HP recommends that you assign target IDs in sequence, and that the EVA has the same target ID
on each host in the SAN.
The following example for an EVA4400 illustrates the binding of targets 20 and 21 (lpfc instance
2) to WWPNs 50001fe100270938 and 50001fe100270939, and the binding of targets 30
and 31 (lpfc instance 0) to WWPNs 50001fe10027093a and 50001fe10027093b:
HP StorageWorks 4400 Enterprise Virtual Array installation guide
http://www.sun.com/
67