Power on Utilities

There are six power-on utilities to set up and test printer hardware. These utilities are
activated by pressing FEED, then turning on the printer power simultaneously and
releasing the button at a different LED color.
Follow these steps for various power-on utilities:
1. Turn off the power switch.
2. Hold the Feed button down, then turn the power switch ON.
3. Release the button when LED indicates a color for a different function.
Power on Utilities
LED Color
Functions
1. Ribbon Sensor Calibration
and Gap / black mark
sensor calibration
2. Gap / black mark sensor
calibration, Self-test and
enter dump mode
3. Printer initialization
4. Set black mark sensor as
media sensor and
calibrate the black
mark sensor
5. Set gap sensor as media
sensor and calibrate the
gap sensor
6. Skip AUTO.BAS
BPP12 User Manual
Amber
Red
Amber
(5 blinks)
(5 blinks)
Release
Release
LED color changes as follows:
Green
Green/Amber
(5 blinks)
(5 blinks)
Release
Release
Red/Amber
Solid
(5 blinks)
green
Release
Release