B-31
Parameter
P.16
Push-Pull Gun Knob Behavior
Determines how the potentiometer on the Push/Pull torch will behave.
• Gun Pot Enabled = The welding wire feed speed is always controlled by the potentiometer on
the push-pull gun (default). The left front panel knob is only used to adjust Start and Crater
wire feed speed.
• Gun Pot Disabled = The wire feed speed is always controlled by the left front panel knob. This
setting is useful when the operator wishes to have wire feed speed settings recalled from
memories and not have the potentiometer "overwrite" the setting.
• Gun Pot Procedure A = When in procedure A, the welding wire feed speed is controlled by the
potentiometer on the push-pull gun. When in procedure B, the welding wire feed speed is con-
trolled by the left front panel knob. This setting allows a fixed wire feed speed to be selected
in procedure B and not have the potentiometer "overwrite" the setting when procedure
changes.
P.80
Sense From Studs
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
reset to False.
• False = Voltage sensing is determined by the DIP switch configuration and the selected weld
mode (default).
• True = Voltage sensing is forced to "studs" regardless of the DIP switch configuration and
selected weld mode.
P.99
Show Test Modes
Most power sources contain weld modes used for calibration and test purposes. By default, the
machine does not include test weld modes in the list of weld modes that are available to the
operator. To manually select a test weld mode, set this option to "Yes". When the power source
is turned off and back on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be connected to a grid load and cannot be used
for welding.
P.100
View Diagnostics
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select
"Yes" to access the diagnostic options in the menu. Additional parameters will now appear in
the setup menu (P.101, P.102, etc).
P.101
View Event Logs
Used for viewing all the system event logs. Press the right MSP Button to enter the option.
Rotate Set knob to select the desired system log to read. Press the right button again to enter
the selected log. Rotating the Set knob will scroll through the event log, displaying the log index
number, event code and some other data. Press the left button to back out to select another
log. Press the left button again to exit this option.
P.102
View Fatal Logs
Used for viewing all the system fatal logs. Press the right MSP Button to enter the option.
Rotate Set knob to select the desired log to read. Press the right button again to enter that log.
Rotating the Set knob will scroll through the log, displaying the log index number and fatal
code. Press the left button to back out to select another log. Press the left button again to exit
this option.
OPERATION
USER DEFINED PARAMETERS
Definition
POWER WAVE
®
C300
B-31