Cold Feed/Gas Purge Switch - Lincoln Electric power wave c300 Operator's Manual

Hide thumbs Also See for power wave c300:
Table of Contents

Advertisement

B-26
B-26
OPERATION

COLD FEED/GAS PURGE SWITCH

COLD FEED
Cold Feed and Gas Purge are com-
bined into a single spring centered tog-
gle switch.
To activate Cold Feeding, hold the
GAS PURGE
switch in the FORWARD position. The
wire drive will feed electrode but neither the power
source nor the gas solenoid will be energized. Adjust
the speed of cold feeding by rotating the WFS knob.
Cold feeding, or "cold inching" the electrode is useful
for threading the electrode through the gun.
Hold with toggle switch in the BACK position to acti-
vate Gas Purge and let the shielding gas flow.
The
gas solenoid valve will energize but neither the power
source output nor the drive motor will be turned on.
The Gas Purge switch is useful for setting the proper
flow rate of shielding gas. Flow meters should always
be adjusted while the shielding gas is flowing.