Outlet Valve Fitting Repair - Graco 16N664 Operation - Repair - Parts

Cordless hand-held paint sprayers
Hide thumbs Also See for 16N664:
Table of Contents

Advertisement

Outlet Valve Fitting Repair

Outlet Valve Fitting Repair
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, remove battery and follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
Move sprayer to a non-hazardous area before servicing.
NOTE: Before doing any repair to pump, perform
Flushing Sprayer procedure, page 15.
Removal
1. Engage trigger lock and pull prime/spray valve UP
to release pressure.
ti18866a
2. Remove battery.
3. Remove outlet valve fitting access plug.
3A2853C
ti16700a
ti14996a
ti16745a
ti15503a
ti18901a
4. Use tool (supplied) to loosen and remove outlet
valve fitting. Make sure old o-ring, seat, outlet valve
fitting, and spring are out of pump outlet cavity.
Installation
1. Screw outlet valve fitting into threads. Use tool
(supplied) and tighten to 8 ft-lb (11 N•m).
2. Press outlet valve fitting access plug into place.