ProShot Repair Kit
ProShot Repair Kit
Outlet Valve Fitting
NOTE: Before doing any repair to pump, perform
Flushing Sprayer procedure, page 13.
Removal
1. Engage trigger lock and pull relief valve UP to
release pressure.
ti14994a
2. Remove battery.
3. Remove pump outlet cap.
3A0153E
ti14999a
ti14996a
ti15503a
4. Use tool (supplied) to loosen and remove outlet
valve fitting.
Installation
1. Screw outlet valve fitting into threads. Use tool (sup-
plied) and tighten to 8 ft-lb.
2. Press new pump outlet cap into place.
ti15506a
ti15508a
ti15507a
17