Remote Voltage/Amperage Control - Miller TRAILBLAZER 302 AIR PAK Owner's Manual

Hide thumbs Also See for TRAILBLAZER 302 AIR PAK:
Table of Contents

Advertisement

6-7. Remote Voltage/Amperage Control

In Example:
Process = Stick (Using Remote On/Off)
Min = 25 A CC/DC
Max = 160 A CC/DC
Connect Remote
V/A Control To
Remote
Receptacle RC4
1
Select DC Output
And Polarity
Set V/A Control
(Mid-Range: About 160 A)
1
Remote Receptacle RC4
Connect optional remote voltage/
amperage (V/A) control to RC4
(see Section 5-11).
Use receptacle to connect remote
control or wire feeder.
When a remote voltage/amperage
control is connected to the Remote
receptacle, the Auto Sense Re-
mote
feature
automatically
switches voltage/amperage con-
trol to the remote control (see Sec-
tions 5-11 and 6-3).
With remote voltage/amperage
control connected, weld output in
CC mode is determined by a com-
bination of front panel and remote
control voltage/amperage settings.
In CV mode, weld output is con-
trolled through remote control only.
If no remote voltage/amperage
control is connected to the Remote
receptacle, the front panel Voltage/
Amperage control adjusts voltage
and amperage.
2
Remote Hand Control
(Optional)
3
Remote Foot Control
(Optional)
.
Engine runs at weld/power
speed in Wire mode whenever
a device connected to the re-
mote receptacle makes clo-
sure between pins A and B. In
all other modes, the engine
runs at idle speed until a load is
applied.
2
Max (160 A DC)
Min (25 A DC)
Adjust Remote V/A Control
(Stick Welding Only)
3
Ref. 804 857-A / Ref. 229 219-A / S-0769 / S-0774