Generator Power Curve; Duty Cycle - Miller TRAILBLAZER 302 AIR PAK Owner's Manual

Hide thumbs Also See for TRAILBLAZER 302 AIR PAK:
Table of Contents

Advertisement

4-6. Generator Power Curve

300
250
200
150
100
50
0
0
20

4-7. Duty Cycle

400
350
300
250
200
150
100
50
0
0
10
13,000 WATTS
40
60
80
AC AMPERES
100% Duty Cycle at 280 Amperes DC
Continuous Welding
DC MIG/FCAW
DC STICK
AC WELD
20
30
40
50
% DUTY CYCLE
100
120
60
70
80
90
100
The AC generator power curve
shows the generator power avail-
able in amperes at the receptacles.
Tools and motors are designed to
operate within 10% of 120/240
VAC.
140
Duty cycle is the percentage of 10
minutes that unit can weld at rated
load without overheating.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.