5-10. Selecting Weld Cable Sizes*

Weld Output
Terminals
!
Stop engine before
connecting to weld
output terminals.
!
Do not use worn,
damaged,
under-
sized,
or
poorly
spliced cables.
This chart is a general guideline and may not suit all applications. If cables overheat, use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

5-11. Remote Receptacle Information

A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used.
OM-229 930 Page 28
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
100 ft (30 m) or Less
10 − 60%
60 − 100%
Welding
Duty
Amperes
Cycle
Cycle
100
4 (20)
150
3 (30)
200
3 (30)
250
2 (35)
300
1 (50)
1/0 (60)
350
1/0 (60)
2/0 (70)
400
1/0 (60)
2/0 (70)
24 VOLTS AC
115 VOLTS AC
REMOTE
OUTPUT
CONTROL
REMOTE
804 857-A
COMPRESSOR
ON/OFF
Not Exceeding***
150 ft
200 ft
(45 m)
(60 m)
Duty
4 (20)
4 (20)
3 (30)
3 (30)
2 (35)
1 (50)
2 (35)
1 (50)
1/0 (60)
1 (50)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
3/0 (95)
4/0 (120)
Socket*
A
24 volts AC. Protected by supplementary protec-
tor CB4.
B
Contact closure to A completes 24 volt AC
contactor control circuit and keeps engine at Run
speed in all modes.
I
115 volts AC. Protected by supplementary protec-
tor CB3.
J
Contact closure to I completes 115 volts AC
contactor control circuit.
C
+10 volts DC output to remote control.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
F
Current feedback: 1 volt per 100 amperes.
H
Voltage feedback: 1 volt per 10 arc volts.
G
Circuit common for 24 and 115 volts AC circuits.
GND
K
Chassis common.
L
Remote compressor on/off (select compressor
output on front panel). Grounding pin L stops com-
pressor.
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 − 100% Duty Cycle
2 (35)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
3/0 (95)
2/0 (70)
3/0 (95)
4/0 (120) 4/0 (120)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
2 ea. 3/0
4/0 (120)
(2x70)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 3/0
(2x70)
(2x95)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 4/0
(2x70)
(2x95)
(2x120)
Socket Information
400 ft
(120 m)
1/0 (60)
3/0 (95)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)