Note: If the sequence is aborted or the Engine Start
Enable Condition expires, normal functionality of the
Rotate Right and Left buttons will return to control
the Chute Motor.
Important: Do not engage starter for more than
10 seconds at a time. If engine fails to start allow
30 second cool-down period between attempts.
Failure to follow these instructions can burn out
starter motor.
5. After the engine starts, move the choke control to the
off position. If the engine stalls or hesitates, move the
choke back to the ON position for a few seconds, then
set the engine speed to the desired setting. Repeat this
as required.
Stopping the Engine
1. Decrease the engine speed midway between the slow
and fast positions.
2. Let the engine idle for 20 seconds.
3. Press the STOP button on the remote control.
4. If leaving the machine, rotate the key to the OFF
position and remove it from the engine (Figure 10).
Start, Stop and Inactivity Time
out
The remote control activates (powers up) when any push
button is pressed. Blinking TX and RX LEDs indicate that
the remote control is alive and communicating with the
base unit. To conserve battery power, the remote control
stays active for approximately three (3) seconds before
automatically shutting down unless there is button activity
within the three second limit. When the unit times out and
powers down, all remote control LED activity stops (Figure
12). Pressing any button will reactivate the remote control
3
4
5
1. Associate
2. Disassociate
3. TX

Power Save Mode

The base unit will revert to Power Save Mode ― until a power
cycle occurs ― if the base unit is active for more than 2.5
hours without communication from the remote control.
Power Save Mode is a low current state of the base unit. In
Power Save Mode, the base unit will not communicate with
the remote control, will not activate outputs, and will not
generally function as normal.
When in the time-out mode the engine will not run (or
will quit running) and the remote control will not control
any function.
To wake controller in time-out mode, turn the key switch
to the OFF position and then turn the key switch to the
start position momentarily (engine will turn over).
To avoid controller time-out during operation, use the
remote control to rotate the chute or change the engine
speed at least every 2.5 hours.