Premaintenance
Procedures

Removing the Hood

To gain additional access to engine compartment, the
hood may be removed from traction unit.
1. Release hood latches (Figure 22) and raise hood.
Figure 22
1. Hood latch
2. Unhook lanyard from hood pin, remove pin and
slide hood tubes rearward off guides (Figure 23).
Figure 23
1. Hood pin

Lubrication

Greasing the Bearings and
Bushings
Service Interval: Every 50 hours
The machine has grease fittings that must be lubricated
regularly with No. 2 General Purpose Lithium Base
Grease. If the machine is operated under normal
conditions, lubricate all bearings and bushings after
every 50 hours of operation or immediately after every
washing.
The grease fitting locations and quantities are as follows:
• Brake shaft pivot bearings (5) (Figure 24)
• Rear axle pivot bushings (2) (Figure 25)
• Steering cylinder ball joints (2) (Figure 26)
32
Figure 24
Figure 25