Premaintenance Procedures; Raising The Mower For Access - Toro GrandStand 74550 Operator's Manual

Mower with a 48in, 52in or 60in turbo force cutting unit
Table of Contents

Advertisement

CAUTION
If you leave the key in the ignition switch, someone could accidently start the engine and seriously injure
you or other bystanders.
Remove the key from the ignition and disconnect the spark plug wires from the spark plugs before you do
any maintenance. Set the wires aside so that they do not accidentally contact the spark plugs.
Premaintenance
Procedures

Raising the Mower for Access

The front of the mower can be raised and supported on
its back for access under the machine for maintenance.
1. Raise the platform. Refer to Operating the Platform
in Operation.
2. Remove the battery.
Figure 32
1. Wing nut
2. Battery cover
3. Negative battery cable
3. Drain the fuel from the fuel tank. Refer to Draining
the Fuel Tank in Maintenance.
4. Remove the cap of the hydraulic tank and place
a piece of plastic over the opening and install the
hydraulic cap. This will seal the hydraulic tank and
prevent it from leaking out.
4. Positive battery cable
5. Battery
1. Cap
2. Piece of plastic
5. With two people, raise the front of the mower so it
rests on the drive tires and the platform in the up
position.
6. Perform any maintenance on the machine.
7. With two people, lower the front of the mower to
the ground.
8. Remove the plastic under the hydraulic tank cap.
9. Install the battery for the machine.
28
Figure 33
3. Hydraulic tank

Advertisement

Table of Contents
loading

Table of Contents