Observe these instructions for your safety.
The burner and control must be correctly installed and
adjusted to ensure safe and economical operation of the
special gas-fired boiler.
Read this installation and maintenance manual carefully
and note the details on the boiler nameplate before
placing the boiler in operation.
1.1

Correct use

The Logano G124X II/SP special gas-fired boiler is
designed to heat water for a hot water heating system
for heating single or multiple occupancy buildings.
1.2

Observe the following symbols

Two levels of danger are identified and signified by the
following terms:
RISK TO LIFE
Identifies possible dangers emanating
from a product, which might lead to serious
WARNING!
injury or death if appropriate care is not
taken.
RISK OF INJURY/
SYSTEM DAMAGE
Identifies potentially dangerous situations,
CAUTION!
which might lead to medium or slight
injuries or to material losses.
Additional symbols for identification of dangers and user
instructions:.
RISK TO LIFE
from electric shock.
WARNING!
USER NOTE
Tip for the optimum utilization and setting
of the control(s) plus other useful
information.
4
Installation and maintenance instructions Logano G124X II/SP special gas-fired boiler • Issue 04/2005
1.3

Please observe these notes

1.3.1 National regulations
The heating system must comply with the relevant
regulations issued by national authorities, or the
regulations issued by the National Fuel Gas Code, ANSI
Z 223.1. In Canada the regulations of CAN/CGA B 149.1
or 2, Installation Code for Gas Burning Appliances and
Equipment, must be observed.
If specified by the local regulatory authorities the heating
system must comply with the regulations of the
"Standard for Controls and Safety Devices for
Automatically Fired Boilers", ANSI/ASME CSD-1.
Carbon monoxide detoectors must be installed as
specified by the local regulations. The boiler must be
serviced annually (
Chapter 13, page 44).
Boiler operating conditions
Maximum boiler temperature
Maximum operating pressure
The hot water pipe system must comply with the current
legislation and regulations. If an existing boiler is
replaced, the complete hot water pipe system must be
inspected to ensure that it is in perfect condition to
ensure safe operation.
RISK TO LIFE
due to neglecting your own safety in case
of emergency, such as with a fire.
WARNING!
Never put yourself at risk. Your own
safety must always take priority.