Specifications - Buderus Logano G124X II/SP Installation And Maintenance Instructions Manual

Hide thumbs Also See for Logano G124X II/SP:
Table of Contents

Advertisement

Specifications

15 Specifications
Main gas orifice identification and rated manifold pressure for natural gas orifice
Boiler size
Number of orifices
18
2
25
3
32
4
Tab. 20 Main gas orifice identification and rated manifold pressure for natural gas orifice
Main gas orifice identification and rated manifold pressure for LP gas orifice
Boiler size
Number of nozzles
18
2
25
3
32
4
Tab. 21 Main gas orifice identification and rated manifold pressure for LP gas orifice
1) factory setting
2) use conversion parts only as directed by the technical
documentation
USER NOTE
If the installation location is over 8500 feet
above sea level, please contact Buderus
for the required conversion components.
Do not attempt to convert the boiler
without the approved Buderus parts and
the relevant technical documentation.
The technical documentation is included with the
conversion parts (accessories).
We reserve the right to make any changes due to technical modifications.
Installation and maintenance instructions Logano G124X II/SP special gas-fired boiler • Issue 04/2005
Main gas orifice identification
for altitudes [feet]
1)
0–8500 ft
285
275
270
Main gas orifice identification
for altitudes [feet]
1)
0–8500 ft
180
175
170
2)
8501–12000 ft
280
270
265
2)
8501–12000 ft
175
170
165
15
Rated manifold
pressure
[in. W.C.]
3.6
3.5
3.6
Rated manifold
pressure
[in. W.C.]
9.8
10.3
10.0
73