Use the following procedure for vertical pole mount installations. The extension arm is recommended when
mounting the Access Point to poles greater than 3 inches is diameter.
For poles up to 3 inches in diameter when using a U-bolt:
1. Thread two 1/2 inch nuts onto the U-bolt.
2. Position the U-bolt on the pole and place the pole mount bracket on the U bolt. Adjust the two 1/2 inch
inner nuts until the pole mount bracket is against the pole and the U-bolt can be secured tightly to the pole
at the desired mounting location.
3. Place the angle adapter bracket on the U-bolt with the open slot connections on the bottom and align it
with the pole mount. Attach with two 1/2 inch nuts. Tighten all nuts to 300 inch pounds (lbf-in).