6.22.2
Ignition transformer
Various ignition transformers are installed in the devices.
Electronic ignition transformer
The integrated electronic ignition transformer (see picture
above) is meanwhile used for all devices, except the devic-
es for special voltages. The electronic ignition transformer
is installed directly on the burner and secured with a screw
that is accessible from the top. Ignition cables are not re-
quired.
Ignition transformer of conventional type with ignition
cable
6.22.3 Flame sensor with holder on the burner
50
English 5.906-432.0 Rev. 00 (06/15)
With older devices or devices for special voltages the con-
ventional ignition transformers are still used.
1 Looking glass
2 Light sensor
3 Flame sensor
1 Screw
2 Holder flame sensor
3 Flame sensor
4 Marking