4.3 INPUT WIRING

CAUTION: Power input common is NOT isolated from user input
common. In order to preserve the safety of the meter application, the
power input common must be suitably isolated from hazardous live earth
referenced voltage; or input common must be at protective earth ground
potential. If not, hazardous voltage may be present at the User Inputs and User Input
Common terminals. Appropriate considerations must then be given to the potential of
the user input common with respect to earth ground; and the common of the plug-in
cards with respect to input common.
Before connecting signal wires, the Input Range Jumper should be verified for proper
position.
4.4 SETPOINT (OUTPUT) WIRING
SINGLE SETPOINT RELAY PLUG-IN CARD
DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD
4.5 SERIAL COMMUNICATION WIRING
SERIAL COMMUNICATIONS PLUG-IN CARD
Current Signal
(self powered)
JUMPER
MAX INPUT
POSITION
CURRENT
µ
200
A
15 mA
2 mA
50 mA
20 mA
150 mA
200 mA
500 mA
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
RJ11 CONNECTOR PIN OUTS
7