Omega Engineering DP63000A-I User Manual

Digital panel meter

Advertisement

Quick Links

User' s Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I
D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I
Digital P P anel M M eter
LP0694A

Advertisement

Table of Contents
loading

Summary of Contents for Omega Engineering DP63000A-I

  • Page 1 User’ s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I Digital P P anel M M eter LP0694A...
  • Page 2 OMEGAnet Online Service ® omega.com Servicing North America: U.S.A.: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A.
  • Page 3: General Description

    GENERAL DESCRIPTION The DP63000 provides the user the ultimate in flexibility, from its complete user programming to the optional setpoint control and communication capability. This unit accepts a DC Current input signal and provides a display in the desired unit of measure. The meter also features minimum and maximum display capture, display offset, units indicator, and programmable user input.
  • Page 4: Specifications

    PROM memory retains all programming parameters and max/min values when power is removed. 10. ENVIRONMENTAL CONDITIONS: Operating Temperature Range for DP63000A-I: -35 to 75°C Operating Temperature Range for DP63000B-I depends on display color and intensity level as per below: INTENSITY LEVEL 1 &...
  • Page 5: Installation Environment

    PTIONAL ADDING OPTION CARDS The DP63000 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below. The plug-in cards, that are sold separately, can be installed initially or at a later date.
  • Page 6: Plug -I N Cards

    3.0 I NSTALLING The Plug-in cards are separately purchased option cards that perform specific functions. The cards plug into the main circuit board of the meter Range Jumpers Comms Card Locking Tab 4.0 W IRING THE WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter.
  • Page 7: Input Wiring

    4.3 INPUT WIRING CAUTION: Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential.
  • Page 8: Programming Menu

    5.0 R EVIEWING THE BUTTON DISPLAY MODE OPERATION Index display through enabled values Resets values (MIN/MAX) or outputs OPERATING MODE DISPLAY DESIGNATORS MAX - Maximum display capture value MIN - Minimum display capture value Pressing the button toggles the meter through the selected displays. If display scroll is enabled, the display will toggle automatically every four seconds between the enabled display values.
  • Page 9: Parameter Menu

    6.1 MODULE 1 - S INPUT RANGE rAN6E RANGE SELECTION RESOLUTION µ 0. 0 2A 200.00 200uA 2.0000 mA 0. 0 02A Select the input range that corresponds to the external signal. This selection should be high enough to avoid input signal overload but low enough for the desired input resolution.
  • Page 10 USER INPUT FUNCTION USrIN DISPLAY MODE DESCRIPTION No Function User Input disabled. See Programming Mode Access chart P-Loc Program Mode Lock-out (Module 3). Zero Input Zero the Input Display value causing ZErO (Edge triggered) Display Reading to be Offset. Resets the assigned value(s) to the Reset (Edge triggered) rESEt current input value.
  • Page 11 6.3 MODULE 3 - D DISPLAY UPDATE TIME dSP-t 0. 5 This parameter sets the display update time in seconds. FRONT PANEL DISPLAY SELECT ENABLE (SEL) selection allows the button to toggle through the enabled displays. FRONT PANEL RESET ENABLE (RST) HI-LO This selection allows the button to reset the selected value(s).
  • Page 12 6.4 MODULE 4 - S The Setpoint Output Parameters are only active when an optional output module is installed in the meter. SETPOINT SELECT SPSEL SP-1 Enter the setpoint (output) to be programmed. The parameters will reflect the chosen setpoint number. After the chosen setpoint is completely programmed, the display will return to each setpoint to be programmed.
  • Page 13 button or user input manual reset, serial reset command or meter power cycle. When the user input or button is activated (momentary action), the corresponding “on” output is reset immediately and remains off until the trigger point is crossed again. (Previously latched alarms will be off if power up Display Value is lower than setpoint value.) = Latch with delay reset action;...
  • Page 14: Programming Quick Overview

    PROGRAMMING QUICK OVERVIEW...
  • Page 15 OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
  • Page 16 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers &...