6.3 MODULE 3 - D
DISPLAY UPDATE TIME
dSP-t
0. 5
1
1
This parameter sets the display update time in seconds.
FRONT PANEL DISPLAY SELECT ENABLE (SEL)
SEL
yES
yES
The
selection allows the
yES
displays.
FRONT PANEL RESET ENABLE (RST)
rSt
NO
HI
dSP
This selection allows the
button to reset the selected value(s).
RST
ZERO DISPLAY WITH DISPLAY RESET
ZErO
yES
NO
This parameter enables the
RST
value, causing the display reading to be offset.
Note: For this parameter to operate, the
must be set to
and the Input value must be displayed. If these conditions are
dSP
not met, the display will not zero.
DISPLAY SCROLL ENABLE
ScroL
yES
NO
The
selection allows the display to automatically scroll through the
yES
enabled displays. The scroll rate is every 4 seconds. This parameter only appears
when the MAX or MIN displays are enabled.
UNITS INDICATOR SELECTION
UNItS
OFF
OFF
This parameter activates the Units Indicator on the display. There are two
methods of selecting the Indicator. List will present a group of Units
preprogrammed into the meter. Segments allows the user to choose which of the
segments should light.
ISPLAY AND
PARAMETER MENU
seconds
2
NO
button to toggle through the enabled
SEL
LO
dSP
HI-LO
NO
button or user input to zero the input display
button or User Input being used
RST
NO
LISt
SEGS
F
P
B
RONT
ANEL
P
ARAMETERS
DISPLAY COLOR (BACKLIGHT UNIT ONLY)
COLOr
rEd
Enter the desired display color, red or green. This parameter is active for
backlight units only.
DISPLAY INTENSITY LEVEL (BACKLIGHT UNIT ONLY)
d-LEV
5
Enter the desired Display Intensity Level (1-5). The display will actively dim
or brighten as levels are changed. This parameter is active for backlight units only.
PROGRAMMING SECURITY CODE
CodE
000
The Security Code determines the programming mode and the accessibility
of programming parameters. This code can be used along with the Program
Mode Lock-out (
) in the User Input Function parameter (Module 1).
P-Loc
Two programming modes are available. Full Programming mode allows all
parameters to be viewed and modified. Quick Programming mode permits only
the Setpoint values to be modified, but allows direct access to these values
without having to enter Full Programming mode.
Programming a Security Code other than 0, requires this code to be entered
at the
prompt in order to access Full Programming mode. Depending on the
CodE
code value, Quick Programming may be accessible before the
appears (see chart).
USER INPUT
USER INPUT
SECURITY
FUNCTION
STATE
CODE
0
1-99
______
not
P-Loc
100-999
0
1-99
Active
P-Loc
100-999
Not Active
0-999
* Entering Code 222 allows access regardless of security code.
11
UTTON
(
)
3-dSP
rEd
6rn
1
5
to
000
999
to
MODE WHEN "SEL"
FULL PROGRAMMING
BUTTON IS PRESSED
MODE ACCESS
Full Programming
Immediate Access
After Quick Programming
Quick Programming
with correct code entry
CodE
at
With correct code entry
CodE
prompt
at
CodE
Programming Lock
No Access
Quick Programming
No Access
With correct code entry
CodE
prompt
at
CodE
Full Programming
Immediate Access
prompt
CodE
prompt *
prompt *
prompt *