NCR, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
Page 3
You are advised to read it carefully. It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with NCR specifications and requirements and all applicable national, state, or local codes, regulations, and laws.
Page 4
“Related Site Preparation Data” section. This book contains the information necessary for the preparation of a site that conforms to NCR specifications. It is very important that the site complies with the requirements specified in the document because,...
Page 5
NCR will not be liable in respect to any comment, suggestion, or advice given by its staff or in respect to any failure to give advice.
Page 8
Mounting Consideration Mounting Considerations Wall Mounting the 7460 Wall Mounting the Complete Unit ......24 Wall Mounting the LCD Operator Display Only..25 7460 System Cables ............27 Environmental Requirements Barometric Pressure ............28 Temperature ..............28 Humidity................ 28 AC Power Line Transient Protection Data Line Transient Protection........
Page 9
NCR is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR.
Model Number 100-120 V/200-240 V, 4.0 A/2.0 A, 50-60 Hz Electrical Ratings (Input) NCR Corporation, 1700 South Patterson Boulevard, Dayton, OH 45459, USA, declares that the equipment specified above conforms to the referenced EU Directives and Harmonized Standards. EU Directive...
18443 This document provides the information necessary to prepare a site to NCR specifications prior to installing a terminal. The site must be properly prepared before the terminal is installed because site preparation deficiencies may be difficult to detect and correct after installation.
Interpreting the Model Number (Example) NCR Model 74xx 20 1 X 80 Language 01 = International English Power Required 80 = 110 -240 VAC 50/60 Hz Operating System 0 = No OS 2 = Windows (NT, 98) 3 = WindowsCE (Future)
Related Site Preparation Data AC Power and Communications Wiring Title Order Number NCR Ethernet Communications Wiring Guide BST0-2118-82 NCR Terminal AC Power Wiring Guidelines BST0-2115-53...
How to Order Information Products are available through several different channels. You need an order form if you are using fax, e-mail, or mail order. Order forms are available to NCR personnel through QuickLook. In QuickLook, click on Forms &...
Provide and install floor coverings and environmental systems that limit or control static electricity build-up and discharge In general, keep the NCR equipment area free from dust, smoke, lint, and other particles. Restrict smoking, eating, and drinking around the equipment. Avoid locating the equipment near other machines that generate ink, carbon, and paper dust particles.
The customer must provide suitable AC power for the web kiosks, associated equipment, and devices. A dedicated unswitched power line dedicated to the NCR equipment installation is recommended. Refer to the Workstation and Peripherals AC Wiring Guide (BSTO- 2115-53) for store AC wiring requirements. The AC outlet must be installed near the web kiosk and easily accessible to the operator.
Physical Considerations This section presents the following information: • Operating and service clearance requirements • Display mounting considerations • Component weights • Airflow requirements • Power requirements...
NCR 7460 Dimensions 292 mm (12 in.) 324 mm 324 mm (12.75 in.) (12.75 in.) 368 mm (14.50 in.) 203 mm (8 in.) 134 mm (5.25 in.) 343 mm (13.50 in.) 18494...
108 mm (4.25 in.) 450.9 mm (17.75 in.) 263.5 mm Operating and Service (10.375 in.) Clearance for Drawer 18038 NCR 2189 Cash Drawer 464 mm (18.25 in.) 133 mm (5.25 in.) 527 mm (20.5 in.) 330 mm (13 in.) Operating and...
(3.75 in.) 450 mm (17.75 in.) 254 mm (10 in.) Operating and Service Clearance for Drawer 17310 NCR 7194 Thermal Receipt Printer 212 mm 130 mm (8.3 in.) (5.10 in.) 85 mm (3.30 in.) 157 mm (6.20 in.) 187 mm (7.4 in.)
Integrated 5973 International VFD Customer Display 262 mm 45 mm (10.3 in.) (1.8 in.) 110 mm (4.3 in.) 350 mm (13.8 in.) 95 mm 95 mm (3.75 in.) 17236a (3.75 in.)
NCR 2336-K007 External CD-ROM Drive 155 mm (6.1 in.) 218 mm (8.6 in.) 23 mm (0.9 in.) 16951 Note: Allow 75 mm (3 in.) clearance in the back of the NCR 2336-K007 External CD-ROM Drive for connector and cable clearance.
Power Requirements Base module contain a three-wire, single-phase, selectable 120/240 volt AC, 120 Watt power supply. The following tables show operating specifications for the power supply. Maximum Input Power Specifications 120 volt 240 volt Voltage Ranges 90 - 136 VAC 198 - 257 VAC Frequency 50/60 Hz...
Page 29
Item Description External Power Source Required Keyboards 0.30 Display 2x20 VFD Powered from 0.50 Serial Port Display 2x20 LCD Powered from 0.10 Serial Port (+12V to +5V conversion in cable) 5992 Signature capture device 0.80 5945 Electronic Payment Device 0.50 7892 Presentation Scanner 0.50 External Parallel Floppy Drive...
Cable Routing Considerations External cables are routed through the bottom of the unit behind the MSR. 1. Remove the MSR by elevating the unit and pulling down and out on the MSR housing as illustrated below: 2. Route cable and return MSR to the as found position. Typical Cable Routing Pull Down and Out...
Mounting Consideration A Tilt Mount terminal can be installed on a flat horizontal surface or a flat vertical surface. 18443 Shown below is the Base Unit option without the Operator LCD. The LCD Mount Access Cover snaps off and on. LCD Mount Access Cover 18831...
Wall Mounting the 7460 The 7460 unit or the Operator Display can be installed on a flat vertical surface. 7460 Wall Mount Operator Display Mount 18835...
Wall Mounting the Complete Unit To install a wall Mount on a flat vertical surface, use the 7460-K533 Wall Mount Bracket Kit . 1. Secure the Wall Plate to the wall with lag screws (4) into the studs or with hardware of similar strength. The recommended viewing height for the terminal is 1.2 m (48") from the floor.
Wall Mounting the LCD Operator Display Only To flush mount the Operators Display on a flat vertical surface, use the K502 Flush Mount Bracket Kit . Flush Mount Flush Mount w/LCD cable penetration through wall 18832...
Page 36
1. Secure the Wall Plate to the wall with lag screws (4) into the studs or with hardware of similar strength. The recommended viewing height for the terminal is 1.2 m (48") from the floor to the center of the screen. Note: If routing cable through the wall drill a hole in the wall for the cable.
Environmental Requirements Barometric Pressure The 7460 Retail Terminal is designed to operate within the following barometric pressure conditions: • Maximum operating altitude: 3000 m (9843 ft) • Operating range of pressure: 105 kPa to 69 kPa (15.2 lb./in. to 10.0 lb./in.)
The NCR Maintenance Agreement does not cover malfunction and/or component failure as a result of power quality problems. NCR accepts no liability for any such occurrence or for its consequences. When power transient suppression is required, the suppressors used should meet the following minimum requirements: •...
Be installed in accordance with all applicable local, state, and national electrical codes and regulations. Note: In certain countries, NCR is able to supply both power and data line transient suppressors as well as a comprehensive line of power conditioning equipment. For application data, contact your NCR...