Connection; Figure 5-10 Connection Configuration Interface; Table 5-8 Connection Configurations - Honeywell Performance HED1PR3 Software Configuration Manual

Hide thumbs Also See for Performance HED1PR3:
Table of Contents

Advertisement

60 | Performance Series IP Camera Software Configuration Guide

Connection

Parameter
Max Connection
TCP Port
UDP Port
HTTP Port
RTSP Port
HTTPs
HTTPs Port
www.honeywell.com/security
Figure 5-10
Connection Configuration Interface
Table 5-8
Connection Configurations
Function
This shows the maximum number of network connections for the same
camera. The value ranges from 1 to 20. The maximum number of
connections is 20.
The default setting is 37777. You can modify this setting as necessary.
The default setting is 37778. You can modify this setting as necessary.
The default setting is 80. You can modify this setting as necessary.
The default setting is 554. The RTSP stream query format is:
Main stream:
rtsp://username:password@ip:port/cam/realmonitor?ch
annel=1&subtype=0
Sub stream:
rtsp://username:password@ip:port/cam/realmonitor?ch
annel=1&subtype=1
You are required to manually enter the following four items: Username,
Password, IP, and Port.
IP: The camera's IP address.
Port: The default is 554. You can leave this field blank if you are using
the default value.
Follow standard RTP protocols. When the encode mode is MJPEG, the
maximum supported resolution is 2040×2040.
Enable the HTTPs port.
The default is 443.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents