Step 4: Installing Anti-Tip
Device
For all ranges, an anti-tip device must be installed as per
these instructions.
WARNING:
RANGE TIPPING HAZARD:
All ranges can tip and injury can result. To prevent
accidental tipping of the range, attach it to the floor,
wall or cabinet by installing the Anti-Tip Device
supplied.
A risk of tip-over may exist if the appliance is not
installed in accordance with these instructions.
If the range is pulled away from the wall for cleaning,
service or for any other reason, ensure that the Anti-Tip
Device is properly re-engaged when the range is pushed
back against the wall. In the event of abnormal usage
(such as a person standing, sitting, or leaning on an
open door), failure to take this precaution can result in
tipping of the range. Personal injury might result from
spilled hot liquids or from the range itself.
WARNING:
ELECTRICAL SHOCK HAZARD:
Use extreme caution when drilling holes into the wall
or floor as there may be concealed electrical wires.
Identify the electrical circuits that could be affected
by the installation of the Anti-Tip Device, then turn off
power to these circuits.
• Failure to follow these instructions may result in
electrical shock or other personal injury.
ATTENTION - PROPERTY DAMAGE
Contact a qualified installer or contractor to determine
the proper method for drilling holes through the wall or
floor material (such as ceramic tile, hardwood, etc.)
Do not slide the range across an unprotected floor.
Failure to follow these instructions may result in
damage to wall or floor coverings.
Tools Needed for Installation of Anti-Tip Device:
Screwdriver, Phillips
Drill, electric or hand
Measuring tape or ruler
1/8" drill bit (wood or metal wall or floor)
Hammer
Pencil or other marker
3/16" carbide-tipped masonry drill bit (concrete or
concrete block wall or floor)
3/16" anchors, drywall or concrete, 4 each (not
required if mounting bracket is being attached to solid
wood or metal).
Thermador
Service Part
Qty
No.
415078
4
647936
1
Important Installation Information:
The anti-tip bracket may be attached to a solid wood
cabinet having a minimum wall thickness of ¾"
(19mm).
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood or metal.
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
Description
Screw, Phillips, #10 x 1½"
Anti-Tip Bracket, Floor-
Mounted