Important Installation Information - Thermador PRD30 Installation Manual

Dual fuel ranges
Hide thumbs Also See for PRD30:
Table of Contents

Advertisement

Available languages

Available languages

Important Installation Information

GAS type verification
Verify the type of gas supplied to the location. Ensure that
the appliance is connected to the type of gas for which it is
certified. All models are certified for use with natural gas.
Field conversion of the appliance for use with propane gas
supply will require a conversion kit (PALPKITHC).
Gas Supply:
Natural Gas — 6 inch water column. (14.9 mb) min., 14
inch (34.9 mb) maximum
Propane Gas — 11 inch water column. (27.4 mb) min., 14
inch (34.9 mb) maximum
Electric Power Supply:
(See page 14 for specifications.)
Check local building codes for the proper method of
appliance installation. Local codes vary and it is the
responsibility of the installer to ensure installation is in
accordance with these codes. Installation, electrical
connections and grounding must comply with all applicable
codes. In the absence of local codes the appliance should
be installed in accordance with the National Fuel Gas Code
ANSI Z223.1/NFPA 54 current issue and National Electrical
Code ANSI/NFPA 70-current issue. In Canada, installation
must be in accordance with the CAN 1-B149.1 and .2 –
Installation Codes for Gas Burning Appliances and/or local
codes.
WARNING:
To avoid possible burn or fire hazard, a backguard
designed specifically for this range must be installed
whenever the range is used.
:
IMPORTANT
When installing against a combustible surface, a High Shelf
or Low Backguard is required. A THERMADOR
Shelf or Low Backguard must be purchased separately.
See Step 7 for backguard, kits and installation information.
English 2
When using the Flush Island Trim, THERMADOR
recommends a minimum 12" (305 mm) rear clearance to a
combustible surface (see Figure 1, Cabinet Clearances).
Clearances from non-combustible materials are not part of
the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12" (305 mm) must be
approved by the local codes and/or by the local authority
having jurisdiction.
Refer to "Chart C: Backguard Kit Model Numbers" on
page 17, for the correct backguard models that are
designed for this range. After selecting the correct
backguard, the range must be installed properly, using the
minimum clearances to combustible surfaces specified in
the Cabinet Preparation instructions beginning on page 4.
Verify that the appliance is correct for the type of gas being
provided. Refer to "Step 5: Gas Requirements and
Hookup" on page 13 before proceeding with the
installation.
When connecting the unit to propane gas, make certain
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator
supplied with the range. The maximum gas pressure to
this appliance must not exceed 14.0" water column
(34.9 mb) from the propane gas tank to the pressure
regulator.
This unit is designed as a cooking appliance. Based on
safety considerations, never use it for warming or
heating a room.
It is strongly recommended that this appliance be installed
in conjunction with a suitable overhead vent hood (see
"Step 1: Ventilation Requirements" on page 3). Due to the
high heat capability of this unit, particular attention should
®
High
be paid to the hood and duct work installation to assure it
meets local building codes.
CAUTION:
CAUTION:

Advertisement

Table of Contents
loading

This manual is also suitable for: