FULL SIZE GAS CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS

MOTOR

electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
1.
Remove BLOWER.
2.
Remove nuts (1, Fig. 24) that secure the motor
mounting plate to rear wall.
Fig. 24
3.
Pull motor assembly into oven cavity and place it
on cardboard.
4.
Remove junction box cover on motor, disconnect
lead wires and remove conduit.
5.
Remove motor mounting bolts and flat washers
then lift the motor from mounting plate.
6.
Position replacement motor on motor mounting
plate and install mounting bolts and washers.
Hand tighten mounting bolts only.
7.
Reconnect lead wires at motor, replace conduit
and junction box cover.
NOTE: Check data plate on motor for wiring
schematic. Motor must rotate clockwise when viewed
from shaft end.
F45598 (0616)
Disconnect the
Page 12 of 35
Fig. 25
8.
Slide blower onto motor shaft until hub is
protruding 1/8".
Fig. 26
9.
Tighten set screws.