Wiring Examples; Maintenance & Care - STEINEL IS 240 DUO Operating Instructions Manual

Hide thumbs Also See for IS 240 DUO:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
Reach setting/adjustment
3
6
Reach setting/examples
16
2

Wiring examples

1. Fixture without neutral conductor
3. Connection via series switch for
manual and automatic operation
1) e.g. 1–4 x 100 W filament bulbs
2) consumer, lighting max. 1000 W (refer to Technical specifications)
3) IS 240 DUO connection terminals
4) indoor switch
5) indoor series switch, manual, automatic
6) indoor double-throw switch, automatic, permanent light
Maintenance/care
The motion sensor is suit-
this purpose. Weather can
able for automatic switching
affect operation of the sensor.
of lights or alarms. The unit
Strong gusts of wind, snow,
is not suitable for special
rain and hail can cause
burglary alarm systems,
switching errors, since the
since it lacks the sabotage
sudden temperature changes
protection prescribed for
cannot be distinguished from
2. Fixture with neutral conductor
4. Connection to double-throw switch for
permanent light and automatic operation
Setting I: automatic operation
Setting II: manual operation for
permanent light
Important: the unit cannot be switched off,
only optional operation between settings I
and II.
heat sources. The detection
lens
4
can be cleaned with
a damp cloth (without
detergents) if dirty.
17