Connection examples

Lamp not fitted with a neutral conductor
Lamp fitted with a neutral conductor
Connection via two-circuit switch for
manual and automatic operation
Connection via a two-way switch for
manual override and automatic operation
Position I: automatic operation
Position II: manual operation
light 'ON' permanently
Note: the system cannot be switched
'OFF', but operated only at settings I and II.
Functions
Once you have connected the unit to the
mains power supply, closed the unit and fitted
the lens, you are ready to put the system into
operation. Two setting options are concealed
Twilight setting (response threshold)
(factory setting:
daylight operation
2000 lux)
2 – 2000 lux
The chosen sensor response threshold is infi-
nitely adjustable from approx. 2 lux - 2000 lux.
Turn control fully anticlockwise to select night-
time operation at about 2 lux. Turn control fully
clockwise to select teach mode, shortly before
this position means daylight operation at about
2000 lux. (The light leaves the factory set to
daylight operation.)
Time setting (switch-'OFF' delay)
(factory setting:
approx. 5 sec.)
5 sec. – 15 min.
a) Load, max. illumination 2000 W
(see Technical specifications)
b) Sensor connection terminals
c) Indoor switch
d) Indoor two-circuit switch, manual,
automatic
e) Indoor two-way switch, automatic,
manual override
Several sensors connected in parallel
(not illustrated)
In this case, it is important not to exceed
a sensor's maximum connected rating.
In addition, all units must be connected to
the same phase.
behind the decorative faceplate.
Important: Only select time and twilight
setting with the lens in place.
Teach mode:
At the light level at which you want the sensor
to respond to movement, the control should
be set to
. After 10 sec. the value of the
ambient brightness is saved.
Dazzle guard
This product is equipped with an integrated
dazzle guard. If blinded by extraneous light,
this puts the sensor into a brightness-related
evaluation mode for 60 sec. (see Trouble-
shooting).
The chosen duration of illumination of the con-
nected lamp is infinitely adjustable between
approx. 5 sec. to a max. of 15 min. (The mo-
tion detector leaves the factory set to the
shortest time.) Any movement detected before
this time elapses will re-start the timer.
Pulse function
The pulse function activates the output for
2 sec. (e.g. for staircase lighting time switches).
16
Manual override function
If a mains switch is installed in the mains supply
lead, the light is capable of the following func-
tions in addition to the simple 'ON'/'OFF' func-
1 x OFF/ON
5 sec. – 15 min.
2 x OFF/ON
4 hours
Operation/Maintenance
The infrared sensor is suitable for switching
'ON' light automatically. The unit is not suitable
for burglar alarm systems as it is not tamper-
proof in the manner prescribed for such sys-
tems. Weather conditions may affect the way
the motion detector works. Strong gusts of
wind, snow, rain or hail may cause the light to
Functional warranty
This STEINEL product has been manufactured
with the utmost care, tested for proper oper-
ation and safety in accordance with applicable
regulations and then subjected to random
sample inspection. STEINEL guarantees that it
is perfect condition and proper working order.
The warranty period is 36 months, starting on
the date of sale to the consumer. We will rem-
edy defects caused by material flaws or manu-
facturing faults. The warranty will be met by
repair or replacement of defective parts at our
own discretion.
This warranty shall not cover damage to wear-
ing parts, damage or defects caused by im-
proper treatment or maintenance.
Further consequential damage to other objects
is excluded.
tion:
Important: The switch should be actuated in
rapid succession (in the 0.5 – 1 sec. range).
Sensor mode
1) Switch light 'ON' (when light is 'OFF'):
Switch 'OFF' and 'ON' once.
Light stays 'ON' for the period selected.
2) Switch light 'OFF' (when light is 'ON'):
Switch 'OFF' and 'ON' once.
Light goes out or switches to sensor mode.
Manual override
1) Activate manual override:
Turn switch 'OFF' and 'ON' twice. The sensor
is set to stay 'ON' for 4 hours (red LED lights
up behind the lens). Then it returns automati-
cally to sensor mode (red LED 'OFF').
2) Deactivate manual override:
Switch 'OFF' and 'ON' once. Light goes out or
switches to sensor mode.
come 'ON' when it is not wanted because the
sensor is unable to distinguish sudden
changes of temperature from sources of heat.
The detector lens may be cleaned with a damp
cloth if it gets dirty (do not use cleaning
agents).
The warranty will only be honoured if the prod-
uct is sent to the appropriate Service Centre
fully assembled and well packed with a brief
description of the fault, receipt or invoice (date
of purchase and dealer's stamp).
Repair Service:
Please ask your nearest service
centre how to proceed for
repairing faults not covered by
the warranty or occurring after
the warranty expires.
17