6
SPECIFICATIONS
GENERATOR
Model
Design
Frequency
Rated Output (COP)
Rated Voltage
Phase & Wire
Power Factor
No. of Poles
Insulation
Voltage Regulation
Type of Coupling
DIESEL ENGINE
Model
Design
No. of cylinders
Bore x stroke
Displacement
Engine speed
Lubricating Oil
Oil capacity
Coolant capacity
SET
Fuel
Fuel consumption (at full load)
Fuel tank capacity
Continuous Operating Hours
Battery (V x Ah/5Hr)
Starting System
L x W x H (with wheel)
Approx Net Wt.
Terminal
Output
Receptacle
Option
Caster
Sound Level (full load at 7m)
Emergency Stop System
AMPS
AMPS
Unit
-STD
Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
Hz
kVA
15
kW
12
V
380
φ-w
%
80
-
-
Rotary coil: Class F, Stator coil: Class B
%
Vertical, water-cooled, 4-cycle diesel engine
mm
L
rpm
L
L
L
L
hrs
mm
kg
-
-
-
-
dB(A)
-
Oil pressure, water temperature, fan belt broken
A
22.8
J315
-AUS
50
15
9
12
9
415
240
3-4
80
100
2
8 (No load to full load)
Direct coupled
D1005-BG-SEC
3
φ76 x73.6
1.001
3000
API service class CD or higher
4.3
3.3
Diesel fuel No. 2 (ASTM D975)
4.5
79
17.0
80D26R(S) (12V x 55Ah)
Electric
1215 x 611 x 922
340
-
-
76.5
In case of abnormal:
20.9
12.5 x 3
J318
-STD
60
17.5
14
220
80
3600
5.8
13.5
-
81.0
45.9

Hide quick links: